Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > ABB Module >
ABB Module REF615 ABB REF 615 ABB REF-615 power BO module board FACTORY SEALED
  • ABB Module REF615 ABB REF 615  ABB REF-615 power BO module board FACTORY SEALED

ABB Module REF615 ABB REF 615 ABB REF-615 power BO module board FACTORY SEALED

Place of Origin Sweden
Brand Name ABB Module
Certification CO.CQ
Model Number REF615
Product Details
Manufacture Year:
2016
Control System:
ABB Module System
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
REF615 ABB REF 615 ABB REF-615 Power BO Module Board
Weight:
4lbs
High Light: 

abb plc

,

advant controller 31

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

ABB Module REF615 ABB REF 615 ABB REF-615 power BO module board FACTORY SEALED

 

Product Description:

 

IResolution in the PLC system: The measured values are converted with a resolution of
12 bits, i.e. 11 bits plus sign for voltage and 12 bits without sign for current. The ranges 0...5 V und ±5 V are converted with 10 bits plus sign.the output A 62,00 is only available for the counter. If the output is to use as a normal digital output, it has to Further details can be found in volume 2, chapter 5.1 "General
information for the use of analog inputs and outputs". In order to make sure, that unused input channels have a defined 0V level, they may be shorted to AGND. Unused inputs must be configured with "unused".
The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows

 

 

ABB Module REF615 ABB REF 615  ABB REF-615 power BO module board FACTORY SEALED 0

 

Related Product Recommendation:

 

TU516 TU516A TC50 DSQC227 YB560103-CE
DI524 ICFC16l1 DSQC223 YB560103-CD
AX522A ICSF08D1 DSQC205 YB560103-BK
AI523 AI523B4 ICSK20F1-120 DSQC201 YB560103-BD
86AR230 ICSK20F1-230 DSQC104 YB560103-AD/1
07KR91B ICSK20F1-24 DSQC 633A YB560103-AB
07SK90R1 ICSK20N1 DSQC 539 6369901-104
23KT92 RTU510 ICSA04B5 DSQC 352A 3HAC 031851-001
07DO90-S ICSE08B5 DSSR170 48990001-PC 3HAC14265-1
07KP90 07KR31 DSSB146
07DC91 07KR31 DSTD150A 48980001-AP/1 DSSB146*BAT2C
07DC91 07KT31 DSTD132
07MK92 07MK62 DSTD108P 57160001-UH
07KT94 35NE90 DSTD108 5716001-FX
07KT94D 35GS91 DSTD 110A 3BSE018333R1
07KT94K 35GS91 DSTC454 5751017-F 57160001-ABD/ABW
07KT94i 35DS91 DSTC190 57520001-ER 57160001-TZ
07KT94 35AB94B DSTA180
07DC92 35AA92C-E DSTA160
07DC92E 35EK90 DSTA131 57120001-CV 57120001-ET
07DC92F 35EK91 DSTA131 57120001-AH
07DC92B 35TP90 DATX130 3ASC25H214 57120001-CV
07AC91 35SK96R1 DAPC100
07DI92 35ST90 DAI05 3ASC25H203
07KT95 35EB92 DAI03 P37131-4-0336025
07KT95 35ZE94 DCP02
07KT97F1 35CS91 3ASU21C110 LU6278 DCU30/7 P-37211-4-0369654

 

Product's Character:

 

In case of a configured plausibility monitoring, range underflow and range overflow by 2...3 % result in an error message (FK4, error number 10). Independent of the configured monitoring, the error values +32767 and -32767 are always generated in case of range underflow and range overflow. Exception: In the measuring range of 0...20 mA only the range overflow is Unused inputs must be configured with "unused". The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows

 

 

ABB Module REF615 ABB REF 615  ABB REF-615 power BO module board FACTORY SEALED 1

 

 


BT 5506a-E HEIA405343R1, HEIA405343R0001 BT5506a-E Module ABB
C1900R Programmable Recorder Module ABB
C201A30301U COMMANDER 200 COMMANDER 200 Temperature Controller ABB
C201C30001U COMMANDER 200 COMMANDER 200 Temperature Controller ABB
C250/0000/STD Commander 250 Universal Process Controller ABB
C250/0100/STD Commander 250 Universal Process Controller ABB
C300/0110/STD Commander 300 Commander 300 ABB
CA-4943013-6 Battery for Memory Backup ABB
CBC01 Batch Command Controller Bailey
CDCMEK-3 Rack Unit ABB
CDP 312 CDP312 Control Panel Keypad ABB
CDP312R Field Kit ABB
CHK-01 Field Kit ABB
CHK-02 Field Kit ABB
CHK-03 Field Kit ABB
CHK-04 Field Kit ABB
CI520V1 3BSE012869R1 CI520V1 AF100 Interface Module ABB
CI522 3BSE012790R1 CI522 AF100 Interface ABB
CI522A 3BSE018283R1 Advant AF100 Interface ABB
CI522AK04 3BSE018451R1 AF100 Communication Interface Kit ABB

CI522AK06 3BSE018453R1 ABB Cable Kit ABB
CI526 3BSE006085R1 CI526 Interface Module ABB
CI526V1 3BSE012870R1 CI526 Interface Module ABB
CI531 3BSE003825R1 RS-232 Interface Submodule ABB
CI532V01 3BSE003826R1 RCOM Interface Submodule ABB
CI532V02 3BSE003827R1 MODBUS Interface ABB
CI532V03 3BSE003828R1 Communication Interface Module - Siemens 3964(R) ABB
CI532V04 3BSE003829R1 AB Interface ABB
CI532V05 3BSE007297R1 Generic MVI Module ABB
CI532V09 3BUP001190R1 Accuray Interface Module ABB
CI534V02 3BSE010700R1 MODBUS Interface Submodule ABB
CI534V04 3BSE010702R1 Allen- Bradley Interface Sub Module ABB
CI535 3BSE003830R1 Free- Programmable MVI Sub Module ABB
CI540 3BSE001077R1 CI540 S100 I/O Bus Extension ABB
CI541 3BSE014665R1 Profibus Interface Sub Module ABB
CI541V1 3BSE014666R1 Profibus Interface Sub Module ABB
CI545 3BSE011063R1 Ethernet MVI Module ABB
CI545V01 3BSE011063R1 Ethernet MVI Module ABB

 

The use of the product:

 
1.electronics manufacturing

2.textile printing and dyeing,

3.machinery,
 
Product's advantages:
 

1.Customer service in 1-4 hours. If there's any question, please contact with our sales.


2.open architecture to take advantage of traditional or renewable sources of energy!


3.We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.

 

 

Our advantages:
 

1.Provides the lowest Total Cost of Ownership (TCO)


2.emission reduction


3.Avoid unplanned downtime

 
Frequently Asked Questions:
 

1 .Q:Does your goods are new and original ?
A: yes ,they are new and original

 

2.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !

 

3.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
 
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us