Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > ABB Module >
ABB Module DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board For new products
  • ABB Module DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board For new products

ABB Module DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board For new products

Place of Origin Sweden
Brand Name ABB Module
Certification CO.CQ
Model Number DSQC236G YB560103-CH
Product Details
Manufacture Year:
2016
Control System:
ABB Module System
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board
Weight:
4lbs
High Light: 

advant ocs

,

advant controller 31

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

ABB Module DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board For new products

 

Product Description:

 

It has to be taken into consideration, that in this application the M terminal of the basic unit 07 KT 94 is
the reference potential. AGND1 is not dimensioned for carrying the sum of the sensor currents. The value of the range underflow is stored. If the ope circuit monitoring is configured, the open-circuit event is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9). The following figure shows the connection of 2-pole passive- type analog sensors 4...20 mA. If the analog current sensors 4...20 mA are powered from a separate power supply unit, the reference potentials 0V (of the separate power supply unit and the power supply unit for the 07 KT 94) must be interconnected to each other.In the above example, the AGND terminal remains
unused.

 

 

 

ABB Module DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board For new products 0

 

Related Product Recommendation:

 

07EA90-S GJR5251200R0101 MAG-XE DRA02 37411-4-0369673
07EB62R1 GJV3074342R1 MAI32MAD DSAB-02C
07KP60R101 GJV3074360R101 MB21 MB 21 DSAI110 57120001-DP
07KP64 GJR5240600R0101 MB510 3BSE002540R1 DSAI145 5712001-HA
07KP90 GJR5251000R0202 MM21 MM 21 DSAO110 57120001-AT
07KR51 MPRC 086349-002 DSAO120A 3BSE018293R1
07KR91 GJR5250000R0101 MV03 MV 03 DSBC110 57310256-E
07KT92 GJR5250500R0902 MZ03 MZ 03 DSBC111 57310256-K
07KT92 GJR5250500R0262 NAIO-01 DSBC173 57310001-KH
07KT93 GJR5251300R0171 NAOM01 DSBC174 3BSE012211R1
07KT94 GJR5252100R0101 NGDR-02C DSBC176 3BSE019216R1
07KT94 GJR5252100R2261 NISA-03 DSCA120 57520001-P
07KT97 GJR5253000R0270 NTAC-02 DSCA125A 57520001-CY
07KT97 WT97 NTAI05 DSCA160A
07KT98 GJR5253100R0270 NTAI06 DSCS140 57520001-EV
07KT98 WT98 NTCL01 DSDC110B 57310001-FT
07KT98 GJR5253100R0270 NTCL01-A DSDI110AV1 3BSE018295R1
07KT98 WT98 NTCS04 DSDI130 57160001-AA
07MK92 GATS110098R0161 NTDI0-A DSDI131 57160001-GV
07MK92 GJR5253300R1161 NTDI01 DSDO115 57160001-NF
07NG61R1 GJV3074311R1 NTRO02 NTRO02-A DSDO115A 3BSE018298R1
07NG63R1 GJV3074313R1 NTRO02-A DSDO120 57160001-AK
07PS62R2 GJV3074332R2 NTRO02-A NTRO02 DSDO131 57160001-KX
07SK90R1 GJR5250200R0001 PAB02 P70870-4-0369059 369059A10 DSDP170 DSDP 170 57160001-ADF
07ZE61R302 GJV3074321R302 PCU-03 DSDX180 3BSE003859R1
07ZE63R302 GJV3074323R302 PE1364B DSDX451L 5716075-AH
BRC300 PHCBRC30000000 PHARPS32200000 DSDX454 5716075-AT
C100/0100/STD PHARPS62200000 DSMB114 57360001-MG
C1900/0263/0260A C1900/0263 PHARPSPEP11013 DSMB116 5736 0001-EB
C1900/0363 C1900/0363/0360A 3BSE012790R1 DSMB144 57360001-EL
XV371A 3BSE018283R1 AI610 3BHT300000R1
PGM03 3BSE018453R1 AI625 3BHT300036R1
PGM09 3BSE006085R1 AI630 3BHT300011R1
PGM35 3BSE003827R1 AI810 3BSE008516R1
3BSE018283R1 3BSE003829R1 AI830A 3BSE040662R1
07SK90R1 GJR5250200R0001 3BSE001077R1 AV31 AV 31

 

Product's Character:

 

The input impedance is ca. 330 Ω. The current input has a self-protecting mechanism. If the input current gets too high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement
will succeed after the current has reached a normal value again. The trigger of the self-protecting mechanism is displayed by the red LED Ovl as long as the overload is present. Inthe PLC system an error message is then stored (FK4, error number 4). The following figure shows the connection of a 3-wire sensor powered by 24 V DC and of a 2-pole sensor powered electrically isolated. Both sensors work as active current sources 0...20 mA.

 

 

 

 

ABB Module DSQC236G YB560103-CH ABB DSQC236G YB560103CH Robotics Axis Board For new products 1

 

 

AO845 3BSE023676R1 Redundant Analog Output Module ABB
AO845A 3BSE045584R1 Redundant Analog Output Module ABB
AO890 3BSC690072R1 Analog Output Module ABB
AO895 3BSC690087R1 Analog Output Module ABB
AO910N 3KDE175533L9100 Analog Output Module ABB
AO930S Analog Output AO930S ABB
AOT-150 PHBAOT15010000 AOT 150 Analog Output Module ABB
AP5524a HTGR 414729 R1, HTGR414729R0001 AP5524a Module ABB
APSAF03 E32086 Safety Board ABB
AT 5513a HEIA404921R1, HEIA404921R0001 AT5513a Module ABB
AV 02 0776011B H&B Contronic AV 02 Module ABB
AV 06 0776005F, 66023-2-0000 H&B AV 06 Contronic Module ABB
AV 07 AV07 H&B AV 07 Contronic Module ABB
AV 08 66011-4-0776007, H&B Contronic AV 08 module ABB
AV 31 0776009D H&B Contronic AV 31 (AV31) Module ABB
AV 41 0776013J H&B Contronic AV 41 Module ABB
AV 42 0776014K H&B Contronic AV 42 Module ABB
AV 43 0776019A H&B Contronic AV 43 (AV43) Module ABB
AV 98 0775909C H&B Contronic AV 98 Module ABB
AW 01 66028-2-0000 H&B Contronic AW 01 Module ABB
AW 02 0776002F H&B Contronic AW 02 Module ABB
AW 03 0776010F, 66025-2-0000 H&B Contronic AW 03 Module ABB
AW 05 0776011B H&B Contronic AW 05 Module ABB
AX210 492953301 Analog Input/Output Module ABB
AX670 3BSE000566R1 Analog Mixed Module ABB
B-5MP9I-A0002 IIATB05 MouseTRAK Trackball ABB
B-5MPBC IIATB05 MouseTRAK Trackball ABB
B6-30-01 Contactor ABB
B6-30-10 Mini Contactor Module ABB
B6-40-00 Contactor ABB

BC810 3BSE030230R1 CEX-Bus Interconnection Unit, ABB
BC810K01 3BSE031154R1 BC810 CEX-Bus Interconnection Unit Kit ABB
BC810K02 3BSE031155R1 CEX-Bus Unit ABB
BRC-100 P-HC-BRC-10000000 BRC100 Harmony Bridge Controller ABB
BRC300 PHCBRC30000000 BRC300 Bridge Controller ABB
BRC400 PHCBRC40000000 BRC400 Bridge Controller ABB
BRC410 SPBRC41000000 S+ Control Processor ABB

 

The use of the product:

 
1.glass industry,

2.oil and gas,

3. petrochemical,
 
Product's advantages:
 

1.Experienced technichal support team.


2. new and original


3.1 year warranty

 

Our advantages:

 

1.Provides the lowest Total Cost of Ownership (TCO)


2.emission reduction


3.Avoid unplanned downtime

 
Frequently Asked Questions:
 

1. Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .

 

 

2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on

 

3.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
 
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us