Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > Allen Bradley Modules >
1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A
  • 1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A
  • 1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A

1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A

Place of Origin USA
Brand Name AB
Certification CO.CQ
Model Number 1756-OF8H
Product Details
Manufacture Year:
2020
Con 6DS1311-8AEtrol System:
1756-OF8H
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
AB
Weight:
4lbs
High Light: 

1756-OF8H

,

Analog Output Module

,

AB 1756-OF8H

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

 

1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A

 

⇒ Click here for good price 1756-OF8H

 

Brand/Manufacturer   AB/USA
Part Number

  1756-OF8H

Alternate Part Number   1756-OF8H
Description   MOTOR SERVO
Dimennsions

  3.5x14.2x14.5cm 

Weight   0.22kg

 

Contact Us

Email: miya@mvme.cn (CLICK)

QQ: 2851195450

Tel: 86-18020776792(CLICK)

Skype:miyazheng520(CLICK)

 

Product Details

The 1756-OF8H ControlLogix Voltage/Current Analog Output Module by AB is an analog output module that has 8 voltage or current outputs with a single HART modem per module. It has a selectable voltage/current signal range of -10.4336-10.4336V and 0-21.2916mA. The 1756-OF8H has an overall output rating of ±10V or 0-20mA and a signal resolution of 15-16 bits for all ranges. It also has a backplane current and voltage range of -10-10.4V or 0-20mA and 4-20mA and a total backplane power of 6.54W. It has a thermal dissipation of 16.78 BTU/hr, and a power dissipation of 4.92W. The 1756-OF8H has an isolation voltage of 50V with basic insulation tested at 1500V AC for 60s between output channels and the backplane.


The 1756-OF8H, unlike other Analog I/O modules, offers Open Circuit Detection and has a circuit detection time at a value that must be set below 0.1 mA. It also offers over-voltage protection and a maximum load resistance of 1 F (voltage) and 10 H (current). Its current settling time without HART is just below 23ms, and below 37ms with HART and its voltage settling time is < 8.5ms to 95% with resistive loads. It has a calibration accuracy (without HART) of 0.1% (voltage) and 0.15% (current) and its standard calibration interval is about 12 months. The 1756-OF8H has an offset drift of 100 V/°C or 200nA/°C and the module has an overall module error of 0.15% (voltage) or 0.3% (current). It adopts the user-defined mechanical keying but the module keying is electronically and software configurable. It has a T4 North America, ATEX, and IEC temperature code, and has an open-style enclosure rating. The 1756-OF8H’s operational temperature ranges between 0 °C and 60 °C at 5-95% non-condensing relative humidity.

1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A 0

 

Our service

100% full New - Original Factory Seal

Warranty: 12 months

Package: Original packing with cartons

Delivery time: Shipped in 3 days after payment

 

More Products 

AB 1756-L1M2 AB 1794-AENT
AB 1769-L30ER AB 1769-ECR
AB 1756-IB32 AB 1756-PLS
AB 1794-TB3 AB 1794-TB3G
AB 1794-IB32 AB 1756-EN2T
AB 1794-OB16P AB 1756-DHRIO
AB 1794-IE12 AB 1794-OB32P
AB 1794-TB32 AB 1336T-MCB-SP51B
AB 1769-IQ16F AB 1756RMC3
AB 1769-PA2 ab 22B-D2P3N104
AB 1756-L71 AB 1756-ENBT

1756-OF8H 1756OF8H AB AB ControlLogix Analog Output Module Series A 1

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us