Automation DCS BERGER LAHR WD5-008.051-00 STEPPER DRIVE Super quality products
Product Description:
Specifies the limit switch to be approached in a reference movement using the commands "ref" and "reff" 0 = Negative limit switch 1 = Positive limit switch 2 = CCW reference switch (as seen from front towards motor shaft) 3 = CW limit switch (as seen from front towards motor shaft) Clearing speed limit switch 1 - 10000 Hz (200) Series 300 Speed when moving out of limit switch or reference switch range 4 - 10000 Hz (200) WDP3-01x Max. allowed distance limit switch 10 - 55924053 (10000) The drive must have left again a limit switch (reference switch) within this distance. Clearing distance limit switch 0 - 1000 steps (0) Clearing distance from limit switch or reference switch after a reference movement (position = 0).
Related Product Recommendation:
MV03 MV 03 | NTRO02-A |
MZ03 MZ 03 | NTRO02-A NTRO02 |
NAIO-01 | PAB02 P70870-4-0369059 369059A10 |
NAOM01 | PCU-03 |
NGDR-02C | PE1364B |
NISA-03 | PHARPS32200000 |
NTAC-02 | PHARPS62200000 |
NTAI05 | CVX-1243-MC2 OZ23 |
NTAI06 | FA-100EN |
NTCL01 | CTC 2207 |
NTCL01-A | 2500-RIO-A |
NTCS04 | 2572-A CTI 2572A |
NTDI0-A | 901B-2589-A |
NTDI01 | 901C-2599 |
NTRO02 NTRO02-A | 901E-2558 |
8DO R 8DOR 1070080680 | CTI 2501 901C-2501 |
BM-DP12 1070075887-202 | 1785T-PMPP-1700 |
BM-DP12 1070075887-304 | 2D78559 2D78559G01 |
D-64711 1070075330-102 | 4A55149H02 |
KM 3300-T 054915-103 KM3300 | AV-007 AIR HYDRO |
RKP-PQ | FLB-60M-03 0190-19674 |
SM 10/20-TA 055128-111 | KF-5-10 |
SM 25/50-TCT DC 560V 25A | CARD 175H3828 DT2 |
WV45-RGC2 0811405119 0 811 405 119 | FCD 311 FCD311PT4P66STR1DCF00T62C0 |
WV60-RGC2 | AKM22C-ANMN2-00 |
804-15005-01 PCB | DEC 30-40382-02 BA353 |
F76CS-1AA | FAS-113DG |
BURR-BROWN MPV901 | ACC-24E2S 603581-101 2-AXIS |
TM-200 | PT-1DA |
IE-3000-8TC-E | AT200-LP |
Product's Character:
Menue "On-line/Controller/Run" 10. Menues "On-line/Test/..." - "FT2000 Simulation" to test FT2000 operation dialogues - "VT52 Emulation" to test terminal operation dialogues - "Debug SEQ Program" to view sequence program part - "Debug PLC Program" to view PLC program part Program test ATTENTION Before switching off power supply the programme transfer must be completed. Important program data will otherwise be destroyed which can only be restored by the Berger Lahr Service. Save program in EEPROM Menue "Online/Controller/Save program to EEPROM
The use of the product:
1.1 year warranty
2.provides integrated control, power, safety,
and information solutions for complete plant-wide control in a scalable,
3.open architecture to take advantage of traditional or renewable sources of energy!
1.Q:Does your goods are new and original ?
A: yes ,they are new and original
2.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
3.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Contact Us at Any Time