ABB Module DSDO120 57160001-AK ABB DSDO120 ASEA BROWN BOVERI DSDO FACTORY SEALED
Product Description:
The analog inputs can be used individually in a lot of different operating modes (even as digital inputs).
The operationg modes are configurable. In order to make sure, that unused input channels have
a defined 0V level, they may be shorted to AGND.In the following, some application examples are shown
for analog sensors.Input currents which exceed the measuring range cause an overflow error message. If the measured value is below the range, an underflow error message is generated.The input impedance is ca. 330 W. The current input has a self-protecting mechanism. If the input current gets too
high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement will succeed after the current has reached a normal value again.
Related Product Recommendation:
YXU149B YT296000-MZ | SCC-F 23212-0-110310 | 140CRA31200 |
8-061588-002 I/O | SD812V1 | 140CRA93100 |
SB1381-B-E-R-A-PM2 | SDCS-CON-2A ADT309600R0002 | 140CRP31200 |
SB1381-C-E-R-A | SDCS-IOB-22 3BSE005177R1 | 140CRP93100 |
HSSI-I016 | SDCS-IOB-3 3BSE004086R1 | 140DAI55300 |
NPSA-TMTA-222 | SNAT 609 SNAT 609 TAI | 140DAI74000 |
ADEPT AWCII 040 | SNAT 609 SNAT609 | 140DAO84000 |
AWCII-040 | SNAT 7261 | 140DAO85300 |
NS700 024 13NS700024/2W | SNAT0100-6B SNAT 0100-6B 61054588 5761852-3B | 140DDI35300 |
BLF-022828 ACC-BOARD | SNAT601TAI | 140DDI35310 |
BLG-022829 | SNAT603CNT SNAT 603 CNT | 140DDO35300 |
R6244 | 6ES5526-3LG0 | 140DDO35301 |
OR4000T | 6ES5535-3LB12 | 140DDO35310 |
MINISEMI 220(380)/15F | 6ES5927-3SA12 | 140DDO36400 |
E1406A | AS-B805-016 | 140NOC78000 |
9300-4EDM | AS-J890-101 | 140NOC78100 |
AT-PWR4 | TM0180-05-05-03-10-02 | 140NOE77101 |
PD-4B PD4B | TM0180-A08-B00-C12-D10 | 140NOE77110 |
YXO126 4890024-UN YXO 126 | TM0180-A08-B00-C15-D10 | 140NOE77111 |
YXT115B 4890024-NK | TM0180-A08-B13-C20-D10 | 140NOM21100 |
YXU144 YT296000-MC YXU 144 | TM0181-A40-B01 | 140NOM21200 |
YXU149 YT296000-RX | TM0182 TM0182-A50-B01-C00 | 170ADO35000 |
XM06B5 1SBP260103R1001 | TM0182-A90-B01-C00 | 170INT11003 |
XN03 XN 03 | 57C404C | 416NHM30032 |
XN05 XN 05 | 57C405-E | 990NAD21110 |
XN06 XN 06 | 586-501-109 M20010003401 | 990XCP98000 |
XO08R1 XOO8R1-B04 1SBP260101R1001 | TH-N12TP | AM-SA85-000 |
Product's Character:
The trigger of the self-protecting mechanism is displayed by the red LED Ovl. as long as the overload is present. In the PLC system an error message is then stored (FK4, error number 4). The open-circuit monitoring begins below ca. 3 mA. The value of the range underflow is stored. If the open-circuit
monitoring is configured, the open-circuit event is displayed by the red LED Ovl. as long as it is present. In the PLC system an error message is stored (FK4, error number 9).
The following figure shows the connection of 2-pole passive- type analog sensors 4...20 mA.
The use of the product:
1. in stock ( help you save time )
2. new and original
3.1 year warranty
1. Q: Do you provide warranty for the goods?
A: Yes, we provide warranty for all the goods from us.
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )