logo
Home > products >
ABB Module
>
ABB Module System DSTA131 57120001AH CONNECTION UNIT DRIVE Highest Version

ABB Module System DSTA131 57120001AH CONNECTION UNIT DRIVE Highest Version

Product Details:
Place of Origin: Sweden
Brand Name: ABB Module
Certification: CO.CQ
Model Number: DSTA131 57120001-AH
Detail Information
Place of Origin:
Sweden
Brand Name:
ABB Module
Certification:
CO.CQ
Model Number:
DSTA131 57120001-AH
Manufacture Year:
2016
Control System:
ABB Module System
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
DSTA131 57120001-AH ABB DSTA131 57120001AH CONNECTION UNIT
Weight:
4lbs
Highlight:

High Light

Highlight:

advant ocs

,

advant controller 31

Trading Information
Minimum Order Quantity:
1
Price:
inquiry
Packaging Details:
new and original with factory sealed
Delivery Time:
today
Payment Terms:
T/T
Supply Ability:
10 pieces a day
Product Description

ABB Module DSTA131 57120001-AH ABB DSTA131 57120001AH CONNECTION UNIT DRIVE Highest version

 

Product Description:

 

Use of analog inputs as digital inputs Several (or all) analog inputs can be configured as digital inputs. When doing so, they evaluate input voltages higher than ca. +7 V as signal 1. The input impedance in this
operating mode is about 4 kW. Terminal M is the reference potential. The input signal delay is 7 ms. It cannot be configured. The inputs are not electrically isolated. they may be shorted to AGND. Unused inputs must be configured with "unused". The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows

 

ABB Module System DSTA131 57120001AH CONNECTION UNIT DRIVE Highest Version 0

 

Related Product Recommendation:

 

07KT98 GJR5253100R0270 PDK02 07KT97B
07KT98 WT98 PDS01 07KT97C
07MK92 GATS110098R0161 PDV01 07KT97
07MK92 GJR5253300R1161 PE01 07KT97B
07NG61R1 GJV3074311R1 PEA01 07KT97B
07NG63R1 GJV3074313R1 PEA02 07KT97B
07PS62R2 GJV3074332R2 PEA03 07KT97B
07SK90R1 GJR5250200R0001 PEB02 07KT98E2
07ZE61R302 GJV3074321R302 PEB03 07MK92
07ZE63R302 GJV3074323R302 PGM01 TC50
086363-002 OSPS2 LL02 ICFC16l1
1700RZ10005C LL03 ICSF08D1
1SAR330020R0000 LM01 ICSK20F1-120
200-CICN 200-CIE LM21 ICSK20F1-230
2012AZ10101B LT02 ICSK20F1-24
35AE92A ER0002081060005 LZ01 ICSK20N1
3ASC25H705/7 LZ02 ICSA04B5
3ASU21C110 LU6278 DCU30/7 MA01 ICSE08B5
3AUA489002B4562 MA02 07KR31
3BHE022291R0101 PCD230A PC D230 A MA03 07KR31
3BHE023784R2530 PP D113 B01-25-111000 MA12 07KT31
3BHE024577R0101 PP C907 BE MB01 07MK62
3BSE001245R1 3BSC640008R1 MB02 35NE90
3BSE003879R1 MB11 35GS91
3BSE011316R1 SDCS-PIN-52 MB12 35GS91
3HAC14550-4 MB21 35DS91
PCZ25 MR01 35AB94B
PCZ28 MS01 35AA92C-E
PDD02 MT01 35EK90
PDK01 MV01 35EK91
07SK90R1 GJR5250200R0001 MV03 35TP90

 

Product's Character:

 

In order to avoid measurement errors, it is absolutely necessary, to lead the cores to the Pt100 sensors in the same cable. The cores must have the same cross section. Per channel, a twisted pair is used (for the two terminals of the Pt100 sensors) plus a single core (half of a twisted pair) for the connection to AGND1. Depending on the configured operating mode, the measured value is assigned linearly as follows the return wire AGND1. In the operating mode "Pt100 in 3-wire configuration" two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured to the desired operating mode, see configuration table Fig. The constant current of the one channel flows through the Pt100 resistance sensor, the constant current of the other channel through one of the wires.
The basic unit 07 KT 94 calculates the measuring value from the two voltage drops and stores it under the odd address

 

 

 

ABB Module System DSTA131 57120001AH CONNECTION UNIT DRIVE Highest Version 1

 

 

CS800-S01-2050-06 Module Drive ABB
DCS800-S02-0025-05 Module Drive ABB
DCS800-S02-0050-05 Module Drive ABB
DCS800-S02-0075-05 Module Drive ABB
DCS800-S02-0100-05 Module Drive ABB
DCS800-S02-0140-05 Module Drive ABB

DCS800-S02-0200-05 Module Drive ABB
DCS800-S02-0260-05 Module Drive ABB
DCS800-S02-0290-06 Module Drive ABB
DCS800-S02-0290-07 Module Drive ABB
DCS800-S02-0350-05 Module Drive ABB
DCS800-S02-0450-05 Module Drive ABB
DCS800-S02-0520-05 Module Drive ABB
DCS800-S02-0900-06 Module Drive ABB
DCS800-S02-0900-07 Module Drive ABB
DCS800-S02-1500-06 Module Drive ABB
DCS800-S02-2000-06 Module Drive ABB
DCS800-S02-2000-07 Module Drive ABB
DD 370A GJR2237400R0001, GJR2237400R1 DD370A Diode Module ABB
DD 371a HEIE 420334 R1 DD 371a Module ABB
DDI 01 P 3711-4-0369626 DDI 01 Digital Input Module ABB
DDI 02 0369637M DDI 02 Digital Input Module ABB
DDI 03 0369643M DDI 03 Digital Input Module ABB
DDI 04 0369643M DDI 03 Digital Input Module ABB
DDO 01 P 37151-4-0369627 DDO 01 Digital Ouput Module ABB
DDO 02 P37151-4-0369642 DDO 02 Digital Ouput Module ABB
DDO 03 P37151-4-0369643 Freelance Digital Output Module ABB
DDO 04 0369644M DDO 04 Digital Output Module ABB
DFC 01 37261-4-0369529 FieldController Main Board ABB
DFE 01 P 37262-4-0369565 Ethernet Module 10Base2 ABB
DFI01 P37112-4-036-9681 Pulse Input Module ABB
DFM 11 P 37262-4-0369575 Profibus DPV1 Module ABB
DFM02 DFM 02 Serial Fieldbus Module ABB
DFP 01 P 37264-4-0369562 FieldController Power Supply Module ABB
DI-24-16 DI2416 Digital Input Module ABB
DI-24-32 FDI2432 Digital Input Module ABB

 

The use of the product:

 
1. electronics manufacturing,

2.energy,

3.transmission and distribution.
 
Product's advantages:
 

1. provides integrated control, power, safety,
and information solutions for complete plant-wide control in a scalable,


2. new and original


3.1 year warranty

 

Our advantages:

 

1.Optimize plant operations


2.emission reduction


3.Avoid unplanned downtime

 
Frequently Asked Questions:
 

1.Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.

 

2.Q:How about the payment terms ?
A:We frequently use T/T

 

3.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
 
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )