Product Description:
Advanced multi-processor design for leading-edge velocity loop bandwidth, fully digital current, velocity, and position loopsLarge-scale integration with custom ASICs and IPMs for performance and reliabilityA 16-bit A/D convertor for precise velocity command input Flash memory for simple field upgrades A personality module to store setup parameters and simplify drive replacement Reduced component count for reliability Internally-shielded filters for electromagnetic compatibility (EMC) Four dedicated I/O plus eight user-selectable, optically isolated digital inputs and outputs (sourcing/active high):Two dedicated inputs Two dedicated outputs Four user-selectable inputs Four user-selectable outputs Two analog inputs for external current limit Two analog outputs for variable monitoring or torque sharing The purpose of this manual is to provide the user with the necessary information to install, program, start up and maintain the Bulletin 1305 drive. To assure successful installation and operation, the material presented must be thoroughly read and understood before proceeding. Particular attention must be directed to the ATTENTION and Important statements contained within.
Related Product Recommendation:
150-SD3NBD | 1442-EC-5040A | 1771-IL |
150-SD3NBR | 1442-EC-5080A | 1771-IR |
150-SD3NUR | 1442-EC-5840A | 1771-NC15 |
150-SDBK | 1442-EC-5840N | 1771-NC6 |
150-SF1 | 1442-EC-5845A | 1771-NIS |
150-SF1R | 1442-EC-5845N | 1771-NR |
150-SF2R | 1442-EC-5880A | 1771-OBD |
150-SF3R | 1442-EC-5880N | 1771-OQ16 |
150-SM2 | 1442-EC-5885A | 1771-OW16 |
150-SM3 | 1442-EC-5885N | 1771-OZL |
150-SM4 | 1442-PR-0803M0505N | 1771-P4R |
150-SM6 | 1442-PR-0803M0510N | 1771-P7 |
150-SPPB1B | 1442-PR-0812E0205N | 1771-SDN |
150-SS | 1442-PR-0812E0210N | 1772-LN2 |
150-STCB | 1442-PS-0503M0010A | 1772-LS |
150-TC1 | 1442-PS-0503M0010N | 1772-LW |
150-TC2 | 1442-PS-0505M0010A | 1772-LX |
150-TC3 | 1442-PS-0505M0010N | 1775-GA |
150B-F135FBD-1-4G-6P-8L | 1442-PS-0507M0010A | 1775-KA |
150B-F135FBDB-3B-5R-BP | 1442-PS-0507M0010N | 1775-L4 |
150B-F201FBD-8B | 1442-PS-0509M0010A | 1775-LX |
150B-F201FBD-HC3 | 1442-PS-0509M0010N | 1775-MEA |
150-SD1NUR | 1442-PS-0512E0010A | 1775-MED |
150-SD2NBD | 1442-PS-0512E0010N | 1775-S4A |
150-SD2NBR | 1442-PS-0512M0010A | 1775-S4B |
150-SD2NUD | 1442-PS-0512M0010N | 1775-S5 |
150-SD2NUR | 1442-PS-0515M0010A | 1746-OBP16 |
1442-PS-0830E0005A | 1442-PS-0515M0010N | 1746-OG16 |
1442-PS-0550E0010A | 1442-PS-0516E0010A | 1746-OV32 |
1442-PS-0550E0010N | 1442-PS-0516E0010N | 1746-OV8 |
1442-PS-0560E0010A | 1440-TB-A | 1746-OW4 |
Product's Character:
The ground conductor of the motor cable should be connected to the drive ground (GRD) terminal directly. Connecting this ground conductor to a cabinet ground point or ground bus bar may cause high frequency current to circulate in the ground system of the enclosure. The motor end of this ground
conductor must be solidly connected to the motor case ground. Shielded or armored cable may be used to guard against radiated emissions from the motor cable. The shield or armor should be connected to the drive ground terminal and the motor ground as outlined in the Grounding section of this Installation
chapter. Common mode chokes are recommended at the drive output to reduce the common mode noise. An RFI filter can be used and in most situations provides an effective reduction of RFI emissions that may be conducted into the main supplylines. If the installation combines a drive with sensitive devices or circuits,it is recommended that the lowest possible drive PWM frequency be programmed.
1771-P4 Power Supply Module AB
1771-P4R Power Supply AB
1771-P4S Power Supply Module AB
1771-P4S1 Power Supply AB
1771-P5 Power Supply AB
1771-P5E Power Supply AB
1771-P6R Power Supply AB
1771-P6S Power Supply AB
1771-P6S1 Power Supply AB
1771-P7 Power Supply AB
1771-PA Power Supply Module AB
1771-PS7 Power Supply Module AB
1771-PS7C Power Supply Assy. 120/220 AC AB
1771-QB Linear Positioning Module AB
1771-RTP4 TYP UMK-SE 11,25-1 902-RTP Remote Termination Panel AB 1
1771-SDN/B 1771-SDN Devicenet Scaner Module AB
1771-SIM Simulator Module AB
1771-SN Sub I/O Scanner Module AB
1771-VHSC Very High Speed Counter Module AB
1771-WA Field Wiring Arm AB
1771-WB Field Wiring Arm,12 Terminals AB
1771-WC Field Wiring Arm AB
1771-WD Field Wiring Arm,12 Terminals AB
1771-WH Field Wiring Arm, 16 I/O channels (21 terminals) AB
1771-WN Field Wiring Arm 32 Terminals AB
1772-CS Processor/Scanner Interconnect Cable AB
1772-LH Processor Interface Module AB
1772-LN2 CPU Module AB
1772-LP2 PLC-2/20 PLC-2/20 Processor Unit AB
1772-LP3 PLC-2/30 PLC-2/30 Processor Unit AB
Thermo Electron 8815A-3SUS-SN EDX Sensor AMAT SemVision cX used working
RH Electronics 50419700200 OM Power Supply Cage OMP AMAT SemVision cX used works
CMC AM422670P000 Motion Controller Aximate/C AMAT SEMVision cX used working
Lambda 40935 Power Supply Alpha 400W AMAT SemVision cX working
Varian 9699504S011 Pump Controller & Cables Turbo-V 250 C.U. SemVision cX works
AMAT SemVision Wafer Transfer Arm Assembly AMAT SemVision cX 300mm works 800-494
MKS 41A12DGA2BA010 10 TORR-G Trip Baratron Pressure Switch 100 TORR-G used works
Brooks 6-0001-0817-SP Robot Rail LTRA 042-SBI AMAT SemVision cX working
AMAT SemVision cX SEM Tilt Motor Assembly used working
Opal ETD Board 50312575100 Circuit Board AMAT SemVision cX working
Opal DVD Board 50312540200 Circuit Board AMAT SemVision cX working
Lambda PA-3N-4-6SG-001 AC DC Power Supply AMAT SemVision cX working
AMAT 50309050000 SEM Electron Column SV300 LT AMAT SemVision cX used working
Opal SRA3 Board 30612530100 Circuit Board AMAT SemVision cX working
Varian Diode Ion Pump Large AMAT SemVision cX used working
VAT 0200X-BA24-AIE2 Pneumatic Slit Valve AMAT SemVision cX used working
Opal MIS2 Board 30612550000 Circuit Board AMAT SemVision cX working
Opal HDF Board 50312510000 Circuit Board 0006300T WD64AA-75AA AMAT SemVision cX
Oram Power Supply LPS850 AMAT SemVision cX working
RH Electronics 50419700100 OM Power Supply Cage OMP AMAT SemVision cX used works
The use of the product:
1.textile printing and dyeing,
2.oil and gas,
3. petrochemical,
1. Optimize plant operations
2. new and original
3.1 year warranty
Our advantages:
1.We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1.Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.
2.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before
3.Q:How about the payment terms ?
A:We frequently use T/T
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )