After starting RSLogix 5000 and either starting a new project or opening an existing project, make sure
that you are OFFLINE with the ControlLogix processor. I/O configuration is only available when offline.
If you have not already defined the contents of your ControlLogix chassis under your project's "I/O
Configuration" folder, you will need to define the ControlNet bridge module at a minimum. Use the right
mouse button to click on the "I/O Configuration" folder, then choose "New Module" from the pop-up menu.From the dialog box that appears, choose the ControlNet bridge of the type (1756-CNB or 1756-CNBR)and series that you are using. In the next screen, you will need to name the ControlNet bridge and
indicate its position in the ControlLogix chassis (slot 0 is the leftmost).After defining the ControlNet bridge, use the right mouse button to click on the ControlNet bridge under"I/O configuration", then choose "New Module" from the pop-up menu
Related Product Recommendation:
152H-C317XBD-54-8L | 1442-PS-0530E0010A | 1485C-P1CG300 |
152H-C317XBD-56 | 1442-PS-0530E0010N | 1485C-P1CG50 |
152H-C317XBD-56-8B | 1442-PS-0540E0010A | 1485C-P1CG600 |
152H-C317XBD-56-8L | 1442-PS-0540E0010N | 1485C-P1E200 |
152H-C361XBD-57-8B | 1442-PS-0550E0010A | 1485C-P1E420 |
152H-C361XBD-57-8L | 1442-PS-0550E0010N | 1485C-P1E75 |
152H-C43XBD-43 | 1442-PS-0560E0010A | 1485C-P1G200 |
152H-C43XBD-44 | 1442-PS-0560E0010N | 1485C-P1G420 |
152H-C43XBD-45 | 1442-PS-0803M0005A | 1485C-P1G75 |
152H-C480XBD-58 | 1442-PS-0803M0005N | 1485C-P1L200 |
152H-C480XBD-58-8B | 1442-PS-0803M0010A | 1485C-P1L420 |
152H-C480XBD-58-8L | 1442-PS-0803M0010N | 1485C-P1L75 |
152H-C480XBD-59 | 1442-PS-0805M0005A | 1485C-P1M5-C |
152H-C480XBD-59-8B | 1442-PS-0805M0005N | 1485C-P1M5-Z5 |
152H-C480XBD-59-8L | 1442-PS-0805M0010A | 1485C-P1N5-C |
152H-C85FBD-47 | 1442-PS-0805M0010N | 1485C-P1N5-M5 |
152H-C85XBD-46 | 1442-PS-0807M0005A | 1485C-P1W100 |
152H-C85XBD-47 | 1442-PS-0807M0005N | 1485C-P1W300 |
152H-C85XBD-47-8B | 1442-PS-0807M0010A | 1485C-P1W5-C |
152H-C85XBD-47-8L | 1442-PS-0807M0010N | 1485C-P1W5-N5 |
152H-C85XBD-48 | 1442-PS-0809M0005A | 1485C-P1W5-Z5 |
152H-C85XBD-48-8B | 1442-PS-0809M0005N | 1485C-P1W600 |
152H-C85XBD-48-8L | 1442-PS-0809M0010A | 1485C-P1X2N5-M5 |
153H-C108XBD-49 | 150-SF2R | 1485C-P1X5N5-M5 |
153H-C135XBD-50 | 150-SF3R | 1485C-R1A150 |
153H-C201XBD-52 | 150-SM2 | 1485C-R1A300 |
153H-C317XBD-54 | 150-SM3 | 1485C-R1A50 |
Product's Character:
For the requested packet interval, enter the number of milliseconds desired between each I/O message
between the ControlLogix processor and the 1203-CN1. The 1203-CN1 can handle a packet interval as
low as 5 milliseconds; therefore, make sure that this value is set to at least Click the "Finish" button to
complete the configuration of the I/O connection in RSLogix 5000. At this point, download your configuration to the ControlLogix processor, then exit RSLogix 5000. To actually schedule the I/O, you will need to start RSNetWorx for ControlNet. Once RSNetWorx starts, go online to the ControlNet network
containing the ControlLogix chassis and 1203-CN1 being configured. Turn on the "Enable Edits" check box, then save the network. This causes the I/O connection created in RSLogix 5000 to be scheduled in the ControlLogix processor. After a few seconds, the I/O LED on the ControlLogix processor and the module LED on the 1203-CN1 should stop blinking and remain green. If they do not, it could indicate a number of I/O-related problems
1785-L40B/C /40 /40 Processor Module - Series C AB
1785-L40B/D /40 /40 Processor Module - Series D AB
1785-L40B/E /40 /40Processor Module - Series E AB
1785-L40C15/E PLC -5/40 PLC -5/40 CONTROLNET Processor - Series E AB
1785-L40C15/F PLC -5/40 PLC -5/40 CONTROLNET Processor - Series F AB
1785-L60B PLC5/60 Processor Module AB
1785-L60B/C PLC -5/60 PLC -5/60 Processor - Series C AB
1785-LT/B Processor Module AB
1785-LT2 /25 /25 Processor Module AB
1785-LT4/A /10, 96077674 /10 Processor AB
1785-ME16 16K EEPROM Memory Cartridge AB
1786-TPYR ControlNet Tap AB
1791-8BC Block I/O Module AB
1792D-16BVT0D 95736401 1792DCBFM INPUT MODULE 16POINT SINK/SOURCE DEVICENET AB
1792D-8BVT0D 95705701 AB Top Input Unit 11-25VDC AB
1792D-CBFM base for: INPUT MODULE 8SINK/SOURCE 4CONNECTORS AB
1793-IB16 Digital Input Module AB
1793-IB16S Digital Input Module AB
1793-IB2XOB2P 24 VDC Combo Module AB
1793-IB2XOB2PS 24 VDC Combo Module AB
1793-IB4 Digital Input Module AB
1793-IB4S Digital Input Module AB
1793-IE2XOE1 Analog Combo Module AB
1793-IE2XOE1S Analog Combo Module AB
1793-IE4 Analog Input Module AB
1793-IE4S Analog Input Module AB
1793-IV16 Digital Input Module AB
1793-IV16S Digital Input Module AB
1793-OB16P Digital Output Module AB
1793-OB16PS Digital Output Module AB
1793-OB4P Digital Output Module AB
1793-OB4PS Digital Output Module AB
1793-OE2 Analog Output Module AB
Bird 1G 1W 310-350 MHz Wattmeter Slug/Element 43+ 1 W Watt Meter
Bird 5L 5 W 1.7-2.2 GHz Wattmeter Element/Slug 1700-2200 MHz for 43+
Bird DPM-50L2 1.25 W-50 W 1900-2200 MHz Wattmeter Element/Slug for DPS/5010
Bird APM-250E 250 W 400-1000 MHz Wattmeter Element/Slug for APM-16
Eimac/Varian Y442/4CW10000A/Y-442/8861 Tube
RCA / Burle 4665 UHF Pulsed Power Amplified Tube (1215 MHz 65kW)
NEW Eimac Y867/Y-867/ 4CX250B/7203 Tube (Made for Fluke)
Bird DPM-5N Plug-in Element/Slug 5 W 2300-2500 MHz for 5010/5000 Series DPS
Bird 25L1 25 W 1.7-1.99 GHz Wattmeter Element/Slug 1700-1990 MHz for 43+
Bird 5L1 5 W 1.7-1.99 GHz Wattmeter Element/Slug 1700-1990 MHz for 43+
Bird 10L1 10 W 1.7-1.99 GHz Wattmeter Element/Slug 1700-1990 MHz for 43+
Bird 50-T-MN Termaline RF Coaxial Termination Dummy Load 50 W, N-Type, 50 Ohms
Bird DPM-50E 1.25 W-50 W 400-960 MHz Wattmeter Element/Slug for DPS/5010 50W
E.F. Johnson 122-0275-001 Socket EF SK-410/400
NEW Eimac SK-600 Air-System Socket & SK-606 Tube Chimney 4X250B/4X250F/4X150F/D
NEW Eimac Y464A/7289/2C39WA/3CX100A5/Y-464A Tube
Bird DPM-.5N Plug-in Element/Slug .5 W 2300-2500 MHz for 5010/5000 DPS
Bird APM-50L 50 W 1700-2200 MHz Wattmeter Element/Slug for APM-16 Plug-In 50W
NEW Mitsubishi FS3SAB45-C 3" Dia. CRT Cathode Ray Tube
The use of the product:
1.Power industry,
2 water, water treatment / environmental protection,
3.municipal engineering,
1. We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.
2. new and original
3.1 year warranty
Our advantages:
1.We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.
2.Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
3.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )