Product Details:
|
|
Place of Origin: | USA |
---|---|
Brand Name: | Allen Bradley Modules |
Certification: | CO.CQ |
Model Number: | 1440-TPR06-00RE |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | inquiry |
Packaging Details: | new and original with factory sealed |
Delivery Time: | today |
Payment Terms: | T/T |
Supply Ability: | 10 pieces a day |
Detail Information |
|||
Manufacture Year: | 2016 | Control System: | Allen Bradley Modules |
---|---|---|---|
Application: | Nuclear Power Plant | Lead Time: | In Stock |
Description: | 1440-TPR06-00RE 1440 TPR06 00RE AB 1440TPR0600RE | Weight: | 4lbs |
High Light: | allen bradley plc 5,controlnet bridge module |
Product Description
Allen Bradley Modules 1440-TPR06-00RE 1440 TPR06 00RE AB 1440TPR0600RE
Product Description:
The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry
for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.).
The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix processor. At
this point, I/O between the ControlLogix processor and the 1203-CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please contact technical support.
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Related Product Recommendation:
1336F-BRF10-AA-EN | 1769-OW8 | 1746-IV16 |
1336F-BRF200-AA-EN | 1769-SM1 | 1746-IV32 |
1336F-BRF50-AA-EN | 1769-SM2 | 1746-N2 |
1336F-BRF75-AE-DE | 1770-KF2 | 1746-NI04I |
1336F-MCB-SP1C | 1770-KFD | 1746-NIO4V |
1336F-MCB-SP1F | 1770-XYC | 1746-NO4I |
1336F-MCB-SP1K | 1771-A2B | 1746-NO4V |
1361-NO61-2-5 | 1771-CP1 | 1746-NR4 |
1394-AM75 | 1771-DB | 1746-NT4 |
1394-SJT05-C-RL? | 1771-DXPS | 1746-OA16 |
1394C-AM04 | 1771-HS3A | 1746-OAP12 |
1394C-AM07 | 1771-IAD | 1746-OB16E |
1395-A65N-C1-PZ | 1771-IAN | 1746-OB8 |
140CRP93100 | 1771-IB | 1746-OBP16 |
1440-ACNR | 1771-IFEK | 1746-OG16 |
1440-DYN02-01RJ | 1771-IFM | 1746-OV32 |
1440-TB-A | 1771-IK | 1746-OV8 |
1440-TBS-J | 1771-IL | 1746-OW4 |
1440-VSE02-01RA | 1771-IR | 1746-OX8 |
1492-XIM4024-16R | 1771-NC15 | 1746-P1 |
15-131623-00 | 1771-NC6 | 1746-P2 |
1734-ACNR | 1771-NIS | 1746SC-IA8I |
1746-BTM | 1771-NR | 1746SC-IN04VI |
1746-C9 | 1771-OBD | 1746SC-INI4I |
1746-FIO4V | 1771-OQ16 | 1746SC-NO8I |
1746-HS | 1771-OW16 | 1756-ENET |
Product's Character:
Manual, gives an overall description of the Bulletin 1305 Adjustable Frequency AC Drive (herein called “the drive”) and provides a listing of key drive options. Additionally, this chapter provides information on receiving and handling the drive. MANUAL OBJECTIVES The purpose of this manual is to provide
the user with the necessary information to install, program, start up and maintain the Bulletin 1305 drive. To assure successful installation and operation, the material presented must be thoroughly read and
understood before proceeding. Particular attention must be directed to the ATTENTION and Important
statements contained within. Chapter 2 provides instructions on how to mount and wire the drive. It also describes how to operate the drive without a Human Interface Module. Read the Motor Cable Length
section on pages 2-13 – 2-16, and the contact closure inputs information in the Control Terminal Block
descriptions on pages 2-19 – 2-21. Chapter 3 defines the display and control panel keys on the optional Human Interface Module. A flowchart is provided to guide the user through the key strokes of the various
menu levels.
1747-OCPCI4 Open Controller PCI Backplane AB
1747-OCVGA1 Open Controller - VGA Interface Module AB
1747-PIC PC Interface Converter AB
1747-PSD Program Storage Device AB
1747-PT1 Hand Held Terminal AB
1747-SCNR ControlNet Scanner Module AB
1747-SDN DeviceNet Scanner Module AB
1747-SN Remote I/O Scanner AB
1747-UIC USB to DH-485 Interface Converter AB
1747OC-EDEBA Open Controller - CPU Module AB
1756-A13/A 13 Slot Chassis - Series A AB
1756-A13/B 13 Slot Chassis - Series B AB
1756-A17/A 17 Slot Chassis - Series A AB
1756-A17/B 17 Slot Chassis - Series B AB
1756-BA2 Battery Assembly AB
1756-CNB/D ControlNet Bridge Module - Series D AB
1756-CNB/E ControlNet Bridge Module - Series E AB
1756-DHRIO/B DH+/RIO Bridge/Scanner Module - Series B AB
1756-DHRIO/C DH+/RIO Bridge/Scanner Module - Series C AB
1756-DHRIO/D DH+/RIO Bridge/Scanner Module - Series D AB
1756-DHRIO/E DH+/RIO Bridge/Scanner Module - Series E AB
1756-DNB/A DeviceNet Bridge/Scanner Module - Series A AB
1756-DNB/B DeviceNet Bridge/Scanner Module - Series B AB
1756-DNB/D DeviceNet Bridge/Scanner Module - Series D AB
1756-DNB/E DeviceNet Bridge/Scanner Module - Series E AB
LAMBDA LRS-54M-12 REGULATED POWER SUPPLY
SIEMENS SIMATIC S5-100U VOLTAGE SELECTOR 6ES5931-8MD11
LAMBDA Electronics FE050048-NA Power Supply AMAT 1140-01269 500W
LAMBDA LFQ-30-1 POWER SUPPLY
SAFW 400 57413077 ED HALL EFFECT TRANSDUCER 209-1021-62
MARWAY POWER SYSTEMS AC DISTRIBUTION UNIT MPD 208A-127 MPD208A
VICOR FLATPAC POWER SUPPLY 95V VI-NUB-EM
LAMBDA LRS-50-15 LRS5015 POWER SUPPLY
LAMBDA LRS 52M-5 POWER SUPPLY
BOC EDWARDS C416-24-000 VACCUUM VALVE 24V 1.25A 7barg
APPLIED MATERIALS 0020-16859-002 0021-78097 RL SMC E/P REGULATOR ITV2011-31N3N4-
YASKAWA VS MINI V7 1.5W CIMR-V7AA20P1 POWER SUPPLY
CONDOR GPC140-24 24VDC, 5.8A, 140w POWER SUPPLY
APPLIED MATERIALS AMAT 3X2H XR80 HIGH VOLTAGE MODULE 9090-00785ITL
Coutant Lambda MML400 4B3NA2A-1297A Omega Power Supply
MKS Instruments 852B61PCA2GC Pressure Transducer 60 PSIA
The use of the product:
1.feed industry,
2.aluminum smelting machines,
3.refrigeration industry.
1.Optimize plant operations
2. new and original
3.1 year warranty
Our advantages:
1.Customer service in 1-4 hours. If there's any question, please contact with our sales.
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1. Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Enter Your Message