Send Message
China Automation DCS manufacturer

MVI56E-MNET Prosoft Modbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix

Product Details:
Place of Origin: USA
Brand Name: Prosoft
Certification: CO.CQ
Model Number: MVI56E-MNET
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: inquiry
Packaging Details: new and original with factory sealed
Delivery Time: today
Payment Terms: T/T
Supply Ability: 10 pieces a day

Detail Information

Manufacture Year: 2016 Control System: MVI56E-MNET
Application: Nuclear Power Plant Lead Time: In Stock
Description: Prosoft Weight: 4lbs
High Light:

b&r touch screen

,

b&r touch panel

Product Description

MVI56E-MNET Prosoft Modbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix

 

MVI56E-MNET

The MVI56E Modbus TCP/IP Client/Server Enhanced Communication Module allows Rockwell Automation ControlLogix processors to interface easily with Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices.

MVI56E enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging though Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files.

The MVI56E-MNET and MVI56E-MNETXT are functionally the same. The MVI56E-MNET is designed for standard process applications. The MVI56E-MNETXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments, at higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.

 

Features and Benefits

Backward Compatibility Upgrade earlier MVI56-MNET modules without changing existing ladder logic programs or module configurations
Enhanced features and flexibility without incurring expensive reprogramming costs
For Extreme Environments(MVI56E-MNETXT Only) Conforms to the EN60079-0 and EN60079-15 standards for applications in caustic and extreme temperature environments
Operates in temperature extremes from -25° to 70° C (-13° to 158° F)
Conformal coating protects against caustic or corrosive environmental elements
RSLogix 5000 Integrated Module communication is integrated within RSLogix 5000 using a sample Add-On Instruction (AOI) or sample ladder logic file
Graphical User Interface Software ProSoft Configuration Builder software (PCB) provides online or offline configuration and diagnostics using high-speed Ethernet port
CIPconnect-enabled, allows remote configuration and dignostic access across multiple bridged EtherNet/IP and ControlNet networks using Rockwell Automation 1756-ENxT and 1756-CNB network interface modules
Web-enabled Ethernet port with Discovery Service Module Ethernet port provides a web server for local access to documentation, module status, and firmware update software
ProSoft Discovery Service, a software utility to locate MVI56E modules on the network and assign a temporary IP address for easy configuration


Specifications

  • Backward compatible with previous MVI56-MNET versions
  • Single-slot 1756 ControlLogix backplane compatible
  • 10/100 Mbps auto crossover detection Ethernet configuration and application port
  • User-definable module data memory mapping of up to 5000 16-bit registers
  • CIPconnect-enabled network configuration and diagnostics monitoring using ControlLogix 1756-ENxT and 1756-CNB modules and EtherNet/IP pass-through communication
  • ProSoft Configuration Builder (PCB) software supported, a Windows-based graphical user interface providing simple product and network configuration
  • Sample ladder logic and Add-On Instructions (AOI) are used for data transfer between module and processor
  • 4-character, alpha-numeric, scrolling LED display of status and diagnostics data in plain English – no cryptic error or alarm codes to decipher
  • ProSoft Discovery Service (PDS) software used to locate the module on the network and assign temporary IP address
  • Personality Module - a non-volatile, industrial-grade Compact Flash (CF) card used to store network and module configuration, allowing quick in-the-field product replacement by transferring the CF card
Specification Description
Backplane Current Load 800 mA @ 5 VDC
3 mA @ 24 VDC
Operating Temperature 0°C to 60°C (32°F to 140°F) - MVI56E-MNET
-25°C to 70°C (-13°F to 158°F) - MVI56E-MNETXT
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Shock 30 g operational
50 g non-operational
Vibration: 5 g from 10 Hz to 150 Hz
Relative Humidity 5% to 95% RH, with no condensation
LED Indicators Battery Status (ERR) Application Status (APP) Module Status (OK)
4-Character, Scrolling, Alpha- Numeric LED Display Shows Module, Version, IP, Application Port Setting, Port Status, and Error Information
Debug/Configuration/Application Ethernet port (E1)
Ethernet Port 10/100 Base-T, RJ45 Connector, for CAT5 cable Link and Activity LED indicators
Auto-crossover cable detection

 


Lead Time : 3-5 Days
Payment:T/T 100% in Advance

Minimum Order Quantity : 1 Piece

Warranty : 1 Year


PROSOFT TRICONEX Bachman MX213
PROSOFT TRICONEX Bachman BS206
PROSOFT TRICONEX Bachman CM202
PROSOFT TRICONEX Bachman CNT204
PROSOFT TRICONEX Bachman DI232
PROSOFT TRICONEX Bachman DIO216
PROSOFT TRICONEX Bachman EM203
PROSOFT TRICONEX Bachman FM211
PROSOFT TRICONEX Bachman FS211/N
PROSOFT TRICONEX Bachman MPC240
PROSOFT TRICONEX Bachman NT255
PROSOFT TRICONEX Bachman PTAI216
PROSOFT TRICONEX Bachman DIO280
PROSOFT TRICONEX Bachman RS204
PROSOFT TRICONEX Bachman BS207
PROSOFT MVI71-ADM Bachman SEM201
PROSOFT MVI71-AFC Bachman BS204
PROSOFT MVI94-MCM Bachman BS205
PROSOFT PS69-DPM EPRO MMS6110

 


 

MVI56E-MNET Prosoft Modbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix 0MVI56E-MNET Prosoft Modbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix 1
MOORE COMPANY
is the world's leading provider of high quality industrial automation spare parts,
whether it is a new spare parts, or outdated / discontinued parts, and the
technology is dedicated to the normal operation of the enterprise at the best
cost, the best quality and efficient way.
Whether it is customer service, work efficiency or delivery speed, we always
strive for excellence and to be better and better.
 
*OTHER BRANDS 
MVI56E-MNET Prosoft Modbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix 2
MVI56E-MNET Prosoft Modbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix 3
 

Get in touch with us

Enter Your Message

You Might Be Into These