logo
Home > Products >
Emerson Spare Parts
>
TREXLHPNAWS1S Emerson Device Communicator PLUS with HART Wireless

TREXLHPNAWS1S Emerson Device Communicator PLUS with HART Wireless

Product Details:
Place of Origin: USA
Brand Name: Emerson
Certification: CO.CQ
Model Number: TREXLHPNAWS1S
Detail Information
Place of Origin:
USA
Brand Name:
Emerson
Certification:
CO.CQ
Model Number:
TREXLHPNAWS1S
Description:
Device Communicator PLUS With HART Wireless
Part Number:
TREXLHPNAWS1S
Brand:
Emerson
Manufacture Year:
2022
Application:
Nuclear Power Plant
Lead Time:
In Stock
Weight:
4lbs
Highlight:

High Light

Highlight:

Emerson Device Communicator HART Wireless

,

Emerson HART wireless communicator PLUS

,

Emerson spare parts device communicator

Trading Information
Minimum Order Quantity:
1
Price:
inquiry
Packaging Details:
new and original with factory sealed
Delivery Time:
today
Payment Terms:
T/T
Supply Ability:
10 pieces a day
Product Description
TREXLHPNAWS1S Emerson Device Communicator PLUS with HART Wireless



Product Description


The TREXLHPNAWS1S is part of Emerson’s AMS Trex™ Device Communicator series — rugged, handheld communicators designed to interface with smart field instruments using the HART® protocol, including WirelessHART® devices. It combines advanced field communication, diagnostics, device configuration, and operational support tools in one portable unit.

More Technical Data
CPU 800 MHz ARM Cortex A8/NXP
Display 5.7″ color VGA resistive touchscreen (glove-friendly)
Typical Operating Time

>8 hours

Operating Temp −20 °C to +55 °C (−4 °F to +131 °F)

Installation and Safety Notes


 

Before Installation

  • Qualified Personnel Only: Ensure only trained personnel handle installation and setup due to risks in electrical and hazardous environments. 
  • Check Certification Ratings: Verify the communicator and field devices meet applicable certifications (i.e., ATEX, CSA, IECEx) and your application’s hazardous area classifications. 
  • Power Off Equipment: Remove or de-energize loops before connecting to avoid accidental ignition or sparks.

Safety Precautions

  • Explosive Atmospheres: Only use in certified hazardous locations; improper use may cause explosion hazards. 

  • Intrinsic Safety: Follow intrinsic safety principles when connecting to live HART loops to prevent ignition sources. 

  • Electrical Shock Risk: Exercise extreme caution when touching leads or terminals. Contact with live circuits can cause serious injury.

  • Hardware Modifications: Do NOT modify or replace parts unless approved; unauthorized changes may compromise safety approvals.

  • General Installation Steps

  • Charge Battery: Fully charge the communicator battery before field use.
  • Connect Leads: Attach HART communication leads to the appropriate terminals, ensuring proper polarity and loop resistance (e.g., 250 Ω resistors where required).
  • Power Up: Power on the communicator and verify screen responsiveness. 
  • Network Setup: Configure wireless (Wi-Fi/NFC) if needed and connect to field assets or host systems. 
  • Test Communication: Confirm communication with the target device before performing diagnostics or configuration. 


Inquiry now: miya@mvme.cn



Our Advantage




All enquiries will be valued and replied with 24 hours.


Quick efficient delivery to guarantee your inventory.


Good package to protect the products.


Sample or small order is welcome.


we will give you any professional suggest, according to different market and products for new customers.


Our Inspect Department will test each batch to ensure high quality, with material test &performance test.


Accept EM ODM our strong design team support custom products according to customer requirement.


Your any feedback will be highly appreciate to make sure we can do better and better.

TREXLHPNAWS1S Emerson Device Communicator PLUS with HART Wireless 0



More Recommended Models


KJ3001X1-CB1 12P1985X062 KJ3202X1-BA1 12P2536X062 VE4032S1T2B1 KJ2201X1-BA1 12P3162X202 SLS1508
KJ3221X1-BA1 12P2531X102 KJ3203X1-BA1 12P3270X032 VE4001S2T2B4 KJ2201X1-BA1 12P3162X092 SLS1508 VS3202
KJ3002X1-BF1 12P1732X082 VE4003S6B1 KJ3201X1-BA1 12P2535X052 VE4001S2T2B2 KJ2201X1-BA1 12P3162X122 SLS1508
KJ2003X1-BB1 12P3439X012 VE3006 KJ4001X1-BA3 12P3378X012 VE3051C0 KJ3202X1-BA1 12P2536X042
PR6424/01 CS CON021 KJ2003X1-BK1 12P4686X052 KJ3223X1-BA1 12P2871X022 VE4003S2B6
KJ1501X1-BC2 12P2186X042 VE5008 KJ2201X1-BA1 12P3162C092 SLS1508 VS3202 PR6423/10R-010 CON021
KJ1501X1-BC3 12P3935X032 VE5009 KJ3222X1-BA1 12P2532X112 VE4003S2B2 PR6423/012-130 CON021
KJ3221X1-BA1 12P2531X122 VE4003S2B2 KJ2002X1-CA1 12P1509X102 VE3004 KJ3203X1-BA1 12P3270X032 CE4001S2T2B4
KJ3222X1-BA1 12P2532X092 VE4003S2B2 KJ3001X1-BG1 12P0557X122 VE4002S1T1B1 PR6423/01R-111 CON031
KJ3222X1-BA1 12P2532X122 VE4033S2B1 KJ3002X1-BB1 12P0683X092 VE3006 KJ3001X1-BB1 12P0550X132 VE4001S2T2


Contact Us



Ready to elevate your automation system? Contact us today for more information or to make a purchase:
Phone:86-18020776792 What’s app: 86-18020776792
Email: miya@mvme.cn Skpye: miyazheng520