logo
Home > Products >
Allen Bradley Modules
>
2711P-B10C4A9 Allen-Bradley Discontinued PanelView Plus 6 1000 Graphic Terminal For Heavy Industrial Plants

2711P-B10C4A9 Allen-Bradley Discontinued PanelView Plus 6 1000 Graphic Terminal For Heavy Industrial Plants

Product Details:
Place of Origin: USA
Brand Name: Allen-Bradley
Certification: CO.CQ
Model Number: 2711P-B10C4A9
Detail Information
Place of Origin:
USA
Brand Name:
Allen-Bradley
Certification:
CO.CQ
Model Number:
2711P-B10C4A9
Display Size & Type:
10.4-inch Color Active-Matrix TFT LCD Screen
Display Resolution:
640 X 480 VGA (18-bit Color Graphics Support)
Operator Input Layout:
Dual Input: 16 Function Keypad + Analog Resistive Touchscreen
Maximum Power Consumption:
65 VA Maximum Power Draw
Internal Storage & Memory:
512 MB RAM / 512 MB Non-volatile Flash Memory
Operating Temperature Window:
0 °C To +55 °C (+32 °F To +131 °F)
Approximate Weight:
2.56 Kg (5.64 Lbs)
Cutout Dimensions (W X H):
252 Mm X 338 Mm (9.92 X 13.31 Inches)
Highlight:

High Light

Highlight:

Discontinued Drop-In Replacement 12-Month Hardware Warranty

,

Rigorous In-House Bench Tested

,

Solid-State Non-Volatile Flash

Trading Information
Minimum Order Quantity:
1
Price:
inquires
Packaging Details:
new and original with factory sealed
Delivery Time:
2-3 work days
Payment Terms:
T/T
Supply Ability:
requires
Product Description
2711P-B10C4A9 Allen-Bradley PanelView Plus 6 1000 Graphic Terminal
Discontinued PanelView Plus 6 1000 Graphic Terminal for Heavy Industrial Plants
Core Value Proposition
Engineered by Allen-Bradley as a rugged operator interface for heavy industrial plants, the 2711P-B10C4A9 is a premium 10.4-inch HMI that delivers flawless dual-input control and real-time visualization for automation teams running critical production lines. By combining an ultra-durable physical keypad with an intuitive touchscreen, it eliminates operational downtime caused by touchscreen failures in dirty or gloved environments—ensuring reliable, high-performance plant monitoring under grueling factory conditions.
Engineer's Technical Review
When replacing a legacy 2711P-B10C4A9, be aware that this unit runs Windows CE 6.0 with the Extended Features package. If you are uploading a FactoryTalk View ME runtime file (`.mer`), ensure your application firmware version targets v6.00 to v12.00 max. Because this specific AC-powered terminal pulls up to 65 VA, ensure your enclosure's thermal dissipation calculation accounts for the internal heat buildup, especially when mounting inside tightly sealed NEMA 4X stainless steel control boxes.
Project Case Study
Deployment Site: Marine Cargo Loading & Logistical Facility, USA
Application: Real-time conveyor routing and HMI interface for critical bulk material handling
Performance Note: Deployed directly inside a dust-heavy outdoor cabinet. The physical F1-F16 keys allowed operators wearing heavy industrial safety gloves to accurately trigger line gates without needing to remove equipment, maintaining 100% operational uptime through intense winter freeze conditions.
Technical FAQ
How can I verify that my terminal is a 2711P-B10C4A9 and not a DC-powered or touch-only variant?
Inspect the white data label adhered to the back panel of the plastic housing. The part number must read exactly `2711P-B10C4A9`. The letter `B` confirms it features both keypad and touch inputs, while the trailing code `A9` indicates it is configured for 100-240V AC power mains running an Extended Windows CE operating system, differentiating it from `D9` DC variants.
Since the PanelView Plus 6 is discontinued by Rockwell, can I directly run my old v5 or v6 HMI program on this unit?
Yes, the 2711P-B10C4A9 has full backward compatibility with legacy FactoryTalk View Studio projects. You can load and restore older `.apa` archive files or transfer your compiled `.mer` runtime files directly via a standard SD card or Ethernet terminal connection, provided the runtime version is compiled for compatibility.
Since Allen-Bradley has moved this series to end-of-life status, what is your current stock availability?
Because factory direct channels face complete component obsolescence, we actively maintain a vetted reserve of factory-sealed, unused surplus 2711P-B10C4A9 modules. This allows plant managers to buy drop-in replacements immediately, bypassing long engineering delays or the costly software migration fees required to rewrite screens for newer PanelView Plus 7 layouts.
Recommended Models
Model Numbers
1756-L63XT | 1757-FIM | 1769-BA | 1756-L64 | 1757-FIMRTP | 1769-L20 | 1756-L65 | 1757-PLX52 | 1769-L31 | 1756-OF6VI | 1757-SRC1 | 1769-OV32T | 1756-OX8I | 1757-SRC3 | 1772-LS | 1756-RIO | 1757-SRM | 1772-LW | 1756-RMC3 | 1761-CBL-HM02 | 1772-LX | 1756-SYNCH | 1761-NET-DNI | 1775-GA | 1757-BEM | 1768-EWEB | 1775-KA | 1757-FFLD2 | 1769-ADN | 1775-L4
Our Leading Advantage Brands
  • Bently Nevada: 3500 Systems, Proximitor sensors, and 3300 XL probes
  • Honeywell: Experion PKS, TDC 3000, and FSC safety systems
  • ABB: 800xA, Symphony Plus, and Bailey INFI 90 DCS
  • Allen-Bradley: ControlLogix 1756 and legacy SLC 500 modules
  • GE Vernova: Mark VI/VIe Speedtronic turbine control cards
  • Triconex: Invensys/Schneider TMR emergency shutdown systems
The Amikon Benefit: 100% Original | Factory Sealed | Lowest Lead Times
Get a Quote Now
Contact: Miya Zheng
WhatsApp: +86 180 2077 6792