logo
Home > Products >
Honeywell Spare Parts
>
HONEYWELL DCS CC-PFB802 51454953-176 8-Segment Fieldbus Interface Module for Process Automation Power Plant

HONEYWELL DCS CC-PFB802 51454953-176 8-Segment Fieldbus Interface Module for Process Automation Power Plant

Product Details:
Brand Name: HONEYWELL
Model Number: CC-PFB802 51454953-176
Detail Information
Brand Name:
HONEYWELL
Model Number:
CC-PFB802 51454953-176
Product Description:
Series C FOUNDATION Fieldbus Interface Module (FIM8) With Eight H1 Networks
Manufacturer:
Honeywell
Model:
CC-PFB802
Part Number:
51454953-176
Physical Interface:
H1 FOUNDATION Fieldbus; 31.25 Kbit/s Per Network
Configuration:
Non-redundant Or Redundant (side-by-side)
Highlight:

High Light

Highlight:

Honeywell CC-PFB802 FIM8 Module

,

51454953-176 8 H1 Networks

,

Series C FOUNDATION Fieldbus Interface

Trading Information
Minimum Order Quantity:
1
Price:
inquires
Packaging Details:
new and original with factory sealed
Delivery Time:
2-3 work days
Payment Terms:
T/T
Supply Ability:
requires
Product Description
HONEYWELL EXPERION SERIES C • VERIFIED MODEL

CC-PFB802
51454953-176

Series C FOUNDATION Fieldbus Interface Module (FIM8) for eight H1 networks. The technical facts below are limited to Honeywell manufacturer documentation.

8H1 networks per FIM 31.25 kbit/sH1 network rate 9.5 Wmodule power dissipation
01 • Exact identity

Order-code-first verification

Manufacturer Honeywell
Model CC-PFB802
Part / order number 51454953-176
Product type Series C FOUNDATION Fieldbus Interface Module (FIM8)
Physical interface H1 FOUNDATION Fieldbus
Construction Series C module, conformally coated
02 • Official technical facts

Documented FIM8 characteristics

H1 networks 8 networks per FIM; each defined as a 31.25 kbit/s H1 network
Configuration Non-redundant or redundant (side-by-side)
Module current 0.380 A at 25 VDC
Power dissipation 9.5 W
Module indicators 24 V power, module status and FTE status LEDs; front display for module and link state
IOTA indicators Eight H1 link-status LEDs, one per link
H1 link connection Using connectors on the applicable IOTA
Engineering check: confirm the complete part number, installed IOTA, redundancy arrangement, Experion release and engineered H1 segment loading before replacement or expansion.
03 • System role

How the FIM8 fits the control architecture

Field layerFOUNDATION Fieldbus H1 devices and engineered segments. Interface layerCC-PFB802 FIM8 manages eight documented H1 network connections. Control layerExperion control architecture through the approved Series C arrangement.
  • Use the FIM8 only with the applicable Honeywell Series C hardware and project configuration.
  • Redundancy, IOTA selection, fieldbus power design and segment capacity are project-specific.
  • Do not infer compatibility from model-family similarity; verify the installed release and complete assembly.
04 • Procurement checklist

Information to confirm before quotation

Exact identity CC-PFB802 and 51454953-176
Installed system Experion release, controller architecture and redundancy arrangement
Termination assembly IOTA model and connector photographs
Network design H1 link allocation, segment loading and fieldbus power arrangement
Visual evidence Module label, front display, connectors and installed-slot photographs
Commercial request Condition, quantity, destination and required date
05 • Independent procurement references

Multi-brand Spare Parts Also Requested

001  LR-TB5000 002  TT430N22KOF 003  6SL3351-6GE41-0AB3
004  6SE7041-8GK85-0HA0 005  KJ3206X1-BA1 006  6SE7090-0XX84-0BA0
007  A5E02915323 008  1900GSR-2USB-C 009  A5E36228237
010  PF2A703H-10-29 011  C98043-A7010-L2 012  A5E01161647
013  SS-1RS6-A 014  CBH215CH506 015  C98043-A7117-L1
016  C98043-A7014-L2 017  C98043-A7017-L1 018  VE4021
019  6SE7032-3HH84-1BH0 020  WDMM002 021  Allen Bradley 2711-K3A10L1X
022  SXWMPC36A10001 023  DC2500-E0-0L00-100-10000-E0-0 024  WDM3-008.9801
025  DC2500-E0-0L00-100-10000-E0-0 UDC2500 026  Allen Bradley 1785KE /C DH+ /RS232 027  ABB YPQ111A
028  ABB YPQ-112B 029  RSBT4895CV0 030  6D55828G12
031  ABB GJR2369900R1100 83SR05E 032  ABB YPC115A 033  ABB PM640 3BSE010534R1
034  MATRIX-410 655-010 035  SGDV-MDA01E4ECA02 036  982200434
037  XV-440-12TSB-1-13-1 038  W40124 ROC800 039  455U-DH-390-W
040  RSBD4855CV0 041  8RU6010-2XX02-1SF0 042  140DDO35310
043  RM4TR33 044  MTL4510 045  NE-1040
046  IC-KP2-2HB6-V15B 047  3TK2803-0AL2 048  ABB 1SVR760669R9400
049  F31X134EPRBHG1 FR00/0 050  FX-48ER-ES 051  CL-LMT.C20DC2 1SVR440721R1300
052  B&R X20IF1061 053  ECL-PTU-207 054  SC22-3E
055  INT-1534-L1-M-1 056  PSD24Ex 057  ETH 2985330
058  IC200UEX626-D 059  D1072S 060  I-7024
061  MN09-90002-69 062  DA-52-3X 063  1000/2x115
064  P-30PSIG-D 065  6SE6440-2AB17-5AA1 066  TDC-000-592
067  19TR-635A-01-3-316 068  HSM-3E4-45 069  22222E
070  21318-C3W33 071  DGSL-20-100-Y3A 072  3LD2164-1GP51-0US1
073  Allen Bradley 1764-28BXB 074  VWDM3538 35H828-1802 075  W54LE 420081
076  RHT0200MD701S1B1100 077  GC-B30 078  GC-S16
079  Z307376050A 093622-3 080  5705APSNKTF 081  1089-0708-01
082  D2T-H18 083  GL-R16H-R GL-RS05 084  21504-000-032-10-02
085  4NC W9326 086  ROERGA40-8-100-T5 087  CACE-14B-523F
088  THC3465 089  21001230 090  4115-0125
091  140M-F8E-C25 092  2080-DNET20 093  WMZT3D20T
094  WMZT3D15 095  736-06-01 096  736-07
097  736-04-01 098  736-01 099  736-02
100  BC20-K40SR-VN 101  6914LLU 102  S3D-P
103  60279233 02670602792332975543 104  SPO-85-22 105  572-5M U-26841
106  CTGPL2020K-16N 107  1609-SBAT 108  2119S-11
109  BRT-THG-2-100 110  TPMN160304 AC405K 111  600506
112  CFH10-1UUR-A 113  AID32A1 A03B-0807-C101 114  4930-4M
115  151.2-25-25 116  311-DXDE 117  177-283
118  RJ45S 841-16/CS13955 U-68359 119  90525 CHS-2.5 120  A35433
121  NFBU200-S05 122  51303940-100 123  FVT86
124  2015828 125  A2BN5D-221D0 126  SDV531-L63/PRP
127  SDVN-4D 128  FVR86 129  VS-IDOOR-24/72
130  706580/08-220-33/020 131  PSM 3010 132  LNS-W11 LX500,PLC-XT35,LC-XG400
133  51402573-250 134  TSX3722001 135  1756-EN2T
136  MVI69-MNET 137  T9110 138  VLC-1188Z-KH
139  ABB OT25ELMM3BZ 140  LM4-LC12J-1A3UN 141  6ES7231-5QD32-0AB0
142  6ES7134-4MB02-0AB0 143  6ES7307-1EA01-0AA0 144  6ES7972-0BA42-0XA0
145  6ES7511-1FK02-0AB0 146  6ES7138-4HA00-0AB0 147  6ES7134-4NB51-0AB0
148  6ES7151-7AA20-0AB0 149  6GK7343-1XE30-0XE0 150  6ES7136-6DB00-0AB0
151  7D0435.7 152  8BVI0028HCS0.000-1 153  700-671-PNC01
154  V600-HAR92 155  8BVI0014HCD0.000-1 156  8BVI0110HWS0.000-1
157  8BVI0028HWDS.000-1 158  4PPC80.121E-10B 159  IF370
160  8B0P0110HW00.000-1

These models are independent procurement references only. They are not substitutes for CC-PFB802 51454953-176. Compatibility and inventory must be confirmed separately for every item.
06 • Retained company media & contact

One consolidated information area

MOORE automation team

MOORE automation company team

Industrial automation sourcing and project support team.

Uploaded company video

The previously uploaded company video is retained once on this product page.

QR code to contact Miya Zheng via WhatsApp

Request a quotation — Contact Miya Zheng

Email: miya@mvme.cn

WhatsApp: +86 180 2077 6792

Include with your inquiry: complete part number, label and connector photos, IOTA model, Experion release, redundancy arrangement, quantity, destination and required date.

07 • Buyer FAQ

Quick verification answers

What is CC-PFB802?
A Honeywell Series C FOUNDATION Fieldbus Interface Module identified as FIM8.
How many H1 networks are documented?
Eight H1 networks, each at 31.25 kbit/s.
Can the module be used redundantly?
Honeywell documents non-redundant or side-by-side redundant configurations; verify the installed project arrangement.
Is another listed model a substitute?
No. Every cross-brand model is an independent procurement reference and requires a separate compatibility and inventory check.
Official source basis: Honeywell Process Solutions, Experion FOUNDATION Fieldbus Integration Specification, EP03-470-510, Release 510, December 2018; and Honeywell System HINTS confirming the FIM8 (CC-PFB802) release. Honeywell Technical Publications · Honeywell System HINTS. No unverified lifecycle, project-result, compatibility or inventory claims are added.