ABB Module 07EA90-S GJR5251200R0101 Advant Controller superior quality product
Product Description:
The module 07 AC 91 offers the following diagnosis functions:Analog value is out of measuring range
Storing this information and possibility for recall(kind of error and location of error)If an error occurs, the red LED lights up. The error message will be transmitted to the central unit or the
coupler.In the central units 07 KR 91 / 07 KT 9x, the errors are .
Related Product Recommendation:
IC200MDL742 | DS200PCCAG5ACB | SKP326-2 |
IC200PWR101 | DS200PCCAG9ACB | ENRZ-AU30 |
IC3600LTGA | DS200PCTMG1AAA | ENRZ-AU40-20 |
IC3600TUAA1 | DS200RTBAG3AEB | ENRZ-TU013-S |
IC609SJR100 | DS200SBCBG1ADC | DSB2S154-211E-000H |
IC660BBD025 | DS200SDCIG1AFB | F4-16AD-2 |
IC670ALG310 | DS200SDCIG2AFB | MCS-20L |
IC670MDL640 | DS200SHVMG1AED | SG2K-1T |
IC670MDL730 | DS200SLCCG1AEG DS215SLCCG1AZZ01B | A02B-0303-C074 |
IC670PBI001 | DS200STBAG1A DS200STBAG1ACB | A03B-0815-C003 |
IC693ACC310 | DS200SVAAG1A DS200SVAAG1ACB | QPI-PSL-201 |
IC693ALG221 | DS200TCQAG1BHF | FIO01-1 P-900163 |
IC693ALG223 | DS200TCQBG1BCB | CUR10 |
IC693ALG392 | DS200TCRAG1ABC | 95DSS2-1 |
F31X139APMALG2FR01 | DS215SLCCG1AZZ01B DS200SLCCG1AEG | 95UVS2-1 |
IC693MDL741C | PR6423/005-031-CN CON041-CN | BLV512 |
531X307LTBAJG1 | PR6423/00C-031-CN CON041-CN | 686B167U05 |
531X309SPCAJG1 | PR6423/00R-101 CON031 | 01984-2518-0002 |
07KT94 GJR5252100R0101 | HCW222A | 01984-4080-0001 |
07KT94 GJR5252100R2261 | XTOP07TW-UD | 01984-4282-0001 |
07KT97 GJR5253000R0270 | 83PKB 83PKB-SM | DLC3010 |
07KT97 WT97 | COMTROL A20056 | DLC3010 0021304771 |
07KT98 GJR5253100R0270 | METEOR/RGB PCI 571-03 | DH7010X1-A1 |
07KT98 WT98 | RX320ER 1100 | LDS9000-3 |
07KT98 GJR5253100R0270 | WATKINS JOHNSON 089714-000 | CPU-30ZBE |
07KT98 WT98 | ATM1850 E2-E3 ATM DSU | SPARC ESP5S-85/0-S |
07MK92 GATS110098R0161 | IMD-310/5F | SYS68K CPU-30BE/16 |
07MK92 GJR5253300R1161 | A413143 BIU84 | SYS68K CPU-30BE16 REV 3 |
07NG61R1 GJV3074311R1 | A413050 | SYS68K/CPU-6 REV. 4.1 |
07NG63R1 GJV3074313R1 | MSXB048-02-E2 | AFS-6VDC-C D464889 |
Product's Character:
After interrogating the last channel and pressing the test button once more, an LED test is initiated. All LEDs of the module must light up. Following this, the position of the DIL address switch is displayed for about 3 seconds (module address on the CS31 system bus). In this case, LED 0 shows the position of switch 1 (LEDs 0...7 are assigned to switches 1...8). Display of an analog value When the test button is not pressed, the analog value of the selected channel is displayed with 8 LEDs. Explanation:all LEDs OFF -> minimum value all LEDs ON -> maximum value
The use of the product:
1. water, water treatment / environmental protection,
2. new and original
3.1 year warranty
1. Q: Do you provide warranty for the goods?
A: Yes, we provide warranty for all the goods from us.
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?