Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > ABB Module >
ABB Module 07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey Performance great
  • ABB Module 07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey Performance great

ABB Module 07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey Performance great

Place of Origin Sweden
Brand Name ABB Module
Certification CO.CQ
Model Number 07NG63R1
Product Details
Manufacture Year:
2016
Control System:
ABB Module System
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey
Weight:
4lbs
High Light: 

abb plc

,

advant controller 31

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

ABB Module 07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey Performance great

 

Product Description:

 

Interface standard EIA RS-232 Programming with 907 AC 1131 with IBM PC (or compatible)Program modifications with 907 AC 1131 with IBM PC (or compatible)Man-machine communication yes, e.g. with an operating station Electrical isolation versus digital inputs and outputs,versus CS31 system bus interface Potential differences In order to avoid potential differences between the 07 KT 98 basic unit and the peripheral devices connected to the COM1/COM2 interfaces, these devices are supplied from the switch-gear cabinet socket Pin configuration and description of the COM1/COM2 interfaces

 

ABB Module 07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey Performance great 0

 

Related Product Recommendation:

 

SNAT603CNT SNAT 603 CNT 07KT98 WT98 CI522 3BSE012790R1
SNAT604IFS SNAT 604 IFS 07KT98 GJR5253100R0270 CI522A 3BSE018283R1
SNAT607MCI SNAT 607 MCI 61027769 07KT98 WT98 CI526 3BSE006085R1
SNAT617CHC SNAT 617 CHC 61037136 07MK92 GATS110098R0161 CI531 3BSE003825R1
SNAT630PAC SNAT 630 PAC 07MK92 GJR5253300R1161 CI532V01 3BSE003826R1
SNAT632PAC SNAT 632 PAC 61049428 07NG61R1 GJV3074311R1 CI532V02 3BSE003827R1
SNAT633PAC SNAT 633 PAC 61049444 07NG63R1 GJV3074313R1 CI532V02 3BSE003827R1
SNAT7780 07PS62R2 GJV3074332R2 CI532V04 3BSE003829R1
SPGU240A1 SPGU 240 A1 07SK90R1 GJR5250200R0001 CI540 3BSE001077R1
SPNPM22 07ZE61R302 GJV3074321R302 CI570 3BSE001440R1
PM645C 3BSE010537R1 07ZE63R302 GJV3074323R302 CI590 3BHT340092R1
NTRO02-A NTRO02 086363-002 OSPS2 CI615 3BHT300024R1
PAB02 P70870-4-0369059 369059A10 1700RZ10005C CI626A 3BSE005023R1
PCU-03 1SAR330020R0000 CI630 3BSE011000R1
PE1364B 200-CICN 200-CIE CI830
07KT92 GJR5250500R0902 2012AZ10101B CI854AK01 3BSE030220R1
07KT92 GJR5250500R0262 35AE92A ER0002081060005 CI857K01 3BSE018144R1
07KT93 GJR5251300R0171 3ASC25H705/7 CI860 CI860K01 3BSE032444R1
07KT94 GJR5252100R0101 3ASU21C110 LU6278 DCU30/7 CM30/000S0E0/STD
07KT94 GJR5252100R2261 3AUA489002B4562 CMA112 3DDE300013
07KT97 GJR5253000R0270 3BHE022291R0101 PCD230A CMA114 3DDE300013
07KT97 WT97 3BHE023784R2530 CMA121 3DDE300401
07KT98 GJR5253100R0270 3BHE024577R0101 PP C907 BE CMA132 3DDE300412
3HAC14550-4 3BSE001245R1 3BSC640008R1 CS300E PAC 031-1053-00
3HAC14551-2 3BSE003879R1 CS513 3BSE000435R1
3HAC17484-8 3BSE011316R1 SDCS-PIN-52 D0910S
3HAC17484-9 3HNM09846-1 DAI01
3HNE00313-1 3HNP04014-1 DAI04
DO620 3BHT300009R1 DSAB-02C DAO01
DO630 3BHT300007R1 DSAI110 57120001-DP DAPC100 3ASC25H203
DO810 3BSE008510R1 DSAI145 5712001-HA DAPC100 3ASC25H203


Product's Character:

 

The desired operating mode is set in a system constant (see documentation part "System technology"). The configured operating mode is only activated during initialization (power-on, cold start, warm start). For all operating modes, the same function block COUNTW is used (see programming software).
Independent of the selected operating mode, the following features are valid:The pulses at the counter input or the evaluated signals at tracks A and B in case of connection of incremental position sensors are counted.The maximum counting frequency is 50 kHz.The counter uses the terminals 2 (E 62,00) and 3
(E 62,01) as fast inputs and, in one operating mode,also the output terminal 46 (A 62,00). In order to make all binary inputs and outputs available for other purposes than counting, it is possible, to disable the
07 KT 98’s counting function.

 

ABB Module 07NG63R1 GJV3074313R1 ABB 07NG63R1 OCS Bailey INFI 90 Bailey Performance great 1

 

The use of the product:

 
1.electronics manufacturing,

2.water, water treatment / environmental protection,

3. textile printing and dyeing,
 
Product's advantages:
 

1.Provides the lowest Total Cost of Ownership (TCO)


2.Optimize plant operations


3.emission reduction

 

Our advantages:
 
Distribution of various brands and specifications of a total of more than 300,000 kinds, and to business mode of operation, to reduce intermediate links for customers in the first time procurement to provide 'safe and efficient' logistics supply system.

We focus on providing customers with cost-effective industrial automation components to help customers improve return on investment, and we in the industrial control and electrical automation spare parts sales have a strong competitive position.
 
Frequently Asked Questions:
 

1.Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.

 

2.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .

 

3.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us