ABB Module AI630 3BHT300011R1 ABB AI630 OPTIBELT supply to worldwide
Product Description:
The "Advant Controller 31" system description are valid. Additional data or data which are different from the system data are listed as follows.Technical data for the complete unit Permissible temperature range during operation 0...55 °C Rated supply voltage 24 V DC Max. current consumption 0.2 A Max. power dissipation 5 W Protection against reversed polarity of power connection yes Number of binary inputs 1 as enabling input for the analog outputs Number of analog input channels 8 or 16, depending on the operating mode Number of analog output channels 8 or 16, depending on the operating mode Electrical isolation CS31 system bus interface from the rest of the unit,1 binary input from the rest of the unit
Address setting and configuration Coding switch under the cover located on the right side of the housing
Related Product Recommendation:
1700RZ10005C | DSTD132 5716001-FX | MM21 MM 21 |
1SAR330020R0000 | DSTD150A 57160001-UH | MPRC 086349-002 |
200-CICN 200-CIE | DSTX120 57160001-MA | MV03 MV 03 |
2012AZ10101B | ECC 086387-001 | MZ03 MZ 03 |
35AE92A ER0002081060005 | ECZ FPR3700001R0001 | NAIO-01 |
3ASC25H705/7 | EL3020 | NAOM01 |
3ASU21C110 LU6278 DCU30/7 | GJR2370500R2 | NGDR-02C |
3AUA489002B4562 | GJV3072403R1 07KR264DR1 | NISA-03 |
3BHE022291R0101 PCD230A PC D230 A | GJV3074353R1 07EA63R1 | NTAC-02 |
3BHE023784R2530 PP D113 B01-25-111000 | HS01 HS 01 | NTAI05 |
07ZE61R302 GJV3074321R302 | ICMK14N1 1SBP260052R1001 | NTAI06 |
07ZE63R302 GJV3074323R302 | ICSA04B5 FPR3341501R1042 | NTCL01 |
086363-002 OSPS2 | ICSE08B5 FPR3346501R1012 | NTCL01-A |
07KT97 GJR5253000R0270 | IDS-DTU51 | NTCS04 |
07KT97 WT97 | IMASI03 | NTDI0-A |
07KT92 GJR5250500R0902 | IMASI23 | NTDI01 |
07KT92 GJR5250500R0262 | IMASO11 | NTRO02 NTRO02-A |
07KT98 WT98 | IMDSI14 | NTRO02-A |
07KT98 GJR5253100R0270 | IMDSI22 | NTRO02-A NTRO02 |
07KT98 WT98 | IMDSO14 | PAB02 |
07MK92 GATS110098R0161 | IMDSO14 IMDS014 | PCU-03 |
07MK92 GJR5253300R1161 | IMFCS01 | PE1364B |
07NG61R1 GJV3074311R1 | IMFEC12 | PHARPS32200000 |
07NG63R1 GJV3074313R1 | IMMPI01 | PHARPS62200000 |
07PS62R2 GJV3074332R2 | IMRIO02 | PHARPSPEP11013 |
07SK90R1 GJR5250200R0001 | IMSED01 | PM150V08 3BSE003641R1 |
07ZE61R302 GJV3074321R302 | IMSET01 | PM253V01 |
07ZE63R302 GJV3074323R302 | INFI90 INFI 90 | PM510 3BSE000270R1 |
086363-002 OSPS2 | INICT03A | PM511V08 3BSE011180R1 |
Product's Character:
The error messages on the module and on the central unit go out again as soon as the error has been corrected, no new errors have been recognized and the error correction was acknowledged.
Acknowledging an error after error correction:by pressing the test button for about 5 seconds, or with the PC, or with the PLC program in the central unit The current input has a self-protecting feature for the
measuring range 0...20 mA. If the current gets too high,the current input shunt is switched off and the value for "overflow" is output. Re-activation is attempted again in increments of approx. 1 second to facilitate the correct measurement as soon as the current regains acceptable limits.
The use of the product:
1.Provides the lowest Total Cost of Ownership (TCO)
2.Avoid unplanned downtime
3.emission reduction
1.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )