Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > ABB Module >
ABB Module CI830 ABB CI830 INTERFACE PROFIBUS Excellent Working Condition
  • ABB Module CI830 ABB  CI830 INTERFACE PROFIBUS Excellent Working Condition

ABB Module CI830 ABB CI830 INTERFACE PROFIBUS Excellent Working Condition

Place of Origin Sweden
Brand Name ABB Module
Certification CO.CQ
Model Number CI830
Product Details
Manufacture Year:
2016
Control System:
ABB Module System
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
CI830 ABB CI830 INTERFACE PROFIBUS
Weight:
4lbs
High Light: 

advant ocs

,

advant controller 31

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

ABB Module CI830 ABB CI830 INTERFACE PROFIBUS Excellent Working Condition

 

Product Description:

 

Diagnosis and displays Short-circuit/overload of outputs (I > 0.7 A)Reporting of a short-circuit or overload condition to the central unit and flashing of the corresponding LED Storing and making this information available for recall (kind of error and location of error) Error inside of module  Error on CS31 system bus
If one of these errors occur, the red LED 3 will light up.The error message will be reported to the central
unit or to the coupler. For additional information refer to chapter "Diagnosis" for these devices.A direct diagnosis inquiry can be made with the test button 4 and the upper LED displays 1 .By pressing the test button once, the channel E/A n, 00 is selected: the status LED of the selected input flashes while all other status indicators are switched off during the test. After releasing the test button, the diagnosis information
for this channel is displayed for about 3 seconds by the upper yellow LEDs 00 to 07.

 

 

ABB Module CI830 ABB  CI830 INTERFACE PROFIBUS Excellent Working Condition 0

 

Related Product Recommendation:

 

3HNP04014-1 CI857K01 3BSE018144R1 DSAO110 57120001-AT
424K1105 CI860 CI860K01 3BSE032444R1 DSAO120A 3BSE018293R1
6638910B1 638910B1PS0084 CM30/000S0E0/STD DSBC110 57310256-E
7944831D CMA112 3DDE300013 DSBC111 57310256-K
89AR30 CMA114 3DDE300013 DSBC173 57310001-KH
A8PU05ABFW02 CMA121 3DDE300401 DSBC174 3BSE012211R1
AI610 3BHT300000R1 CMA132 3DDE300412 DSBC176 3BSE019216R1
AI625 3BHT300036R1 CS300E PAC 031-1053-00 DSCA120 57520001-P
AI630 3BHT300011R1 CS513 3BSE000435R1 DSCA125A 57520001-CY
AI810 3BSE008516R1 D0910S DSCA160A
AI830A 3BSE040662R1 DAI01 DSCS140 57520001-EV
AV31 AV 31 DAI04 DSDC110B 57310001-FT
3HNE00313-1 DAO01 DSDI110AV1 3BSE018295R1
3HNM09846-1 DAPC100 3ASC25H203 DSDI130 57160001-AA
07NG63R1 GJV3074313R1 DAPC100 3ASC25H203 DSDI131 57160001-GV
07PS62R2 GJV3074332R2 DAPU100 3ASC25H204 DSDO115 57160001-NF
CI522 3BSE012790R1 DATX110 3ASC25H209 DSDO115A 3BSE018298R1
CI522A 3BSE018283R1 DATX130 3ASC25H214 DSDO120 57160001-AK
CI526 3BSE006085R1 DATX132 3ASC25H216 DSDO131 57160001-KX
CI531 3BSE003825R1 DCF503-0050 DSDP170 DSDP 170 57160001-ADF
CI532V01 3BSE003826R1 DCP02 P-37211-4-0369654 DSDX180 3BSE003859R1
CI532V02 3BSE003827R1 DCP10 DSDX451L 5716075-AH
CI532V02 3BSE003827R1 DDI01 07SK90R1 GJR5250200R0001
CI532V04 3BSE003829R1 DDO01 07ZE61R302 GJV3074321R302
CI540 3BSE001077R1 DI685 3BDS005833R1 07ZE63R302 GJV3074323R302
CI570 3BSE001440R1 DI811 3BSE008552R1 086363-002 OSPS2
CI590 3BHT340092R1 DIGITRIC 500 61615-0-1200000 1700RZ10005C

 

Product's Character:

 

An address must be set for each module to enable the central unit to correctly access the inputs and outputs.A detailed description about "Addressing" can be found in the chapter "Addressing" for the central processing unit and coupler.The address setting is accomplished with the DIL switch located under the slide cover on the right side of the module housing.When using cental units 07 KR 91 or 07 KT 9x as bus
master, the following possibilities (address assignments)are offered, depending on the setting of the address DIL switch  Item n in the table designates the module address that can be set with the address DIL switch with switches 2...7. When using 07 KR 91 / 07 KT 9x as bus master, we recommend to use even-numbered module addresses (08,10, 12......60).In this setting, (DIL switch 1 in OFF position = factory setting) the module occupies two addresses for inputs and outputs.

 

ABB Module CI830 ABB  CI830 INTERFACE PROFIBUS Excellent Working Condition 1

 

The use of the product:

 
1.automobile manufacturing,

2.chemical,

3. petrochemical,
 
Product's advantages:
 

1.Provides the lowest Total Cost of Ownership (TCO)


2.machinery,


3.emission reduction

 

Our advantages:
 
Distribution of various brands and specifications of a total of more than 300,000 kinds, and to business mode of operation, to reduce intermediate links for customers in the first time procurement to provide 'safe and efficient' logistics supply system.

We focus on providing customers with cost-effective industrial automation components to help customers improve return on investment, and we in the industrial control and electrical automation spare parts sales have a strong competitive position.
 
Frequently Asked Questions:
 

1.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .

 

 

2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on

 

3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us