ABB Module DSBC111 57310256-K ABB DSBC111 BUS TERMINATION MODULE High reliability
Product Description:
Diagnosis functions Short-circuit/overload of outputs (I > 0.7 A) Reporting of a short-circuit or overload condition to the central unit and flashing of the corresponding LED Storing and making this information available for recall (kind of error and location of error) Error inside of module Error on CS31 system bus
If one of these errors occur, the red LED 3 will light up.The error message will be reported to the central
unit or to the coupler. For additional information refer to chapter "Diagnosis" for these devices.
A direct diagnosis inquiry can be made with the test button 4 and the upper LED displays 1 .By pressing the test button once, the channel E/A n, 00 is selected: the status LED of the selected input flashes
while all other status indicators are switched off during the test. After releasing the test button, the diagnosis information for this channel is displayed for about 3 seconds by the upper yellow LEDs 00 to 07.
Related Product Recommendation:
6DD1600-0AK0 | AD916AG FBM204 | 140CRA31200 |
6DD1606-1AA0 | OYDE-S BF0C 943 178-101 | 140CRA93100 |
6DD1606-2AC0 | RS2-TX | 140CRP31200 |
6DD1607-0EA1 | EH1*A | 140CRP93100 |
6DD1640-0AC0 | EP3*A | 140DAI55300 |
6DD1661-0AB1 | ER5*B | 140DAI74000 |
6DD1662-0AB0 | PC10031 | 140DAO84000 |
6DD1670-0AF0 | 240-1CA00 | 140DAO85300 |
6DD1681-0AH2 | FP-AI-100 | 140DDI35300 |
6DD1681-0EK1 | 5610102050 | 140DDI35310 |
6DD1683-0BC0 | TDM2.1-030-300-W1 | 140DDO35300 |
6DD1683-0BC5 | MIEF1203-P-SC-2-A220-V5.0 | 140DDO35301 |
6DD1688-0AD0 | TRY/PRG/4-20MA/10-30DC | 140DDO35310 |
6DD3460-0AC0 | MVME162-433 | 140DDO36400 |
6DM1001-2LA02-2 | AS-B805-016 | 140NOC78000 |
6DR2004-1 | AS-J890-101 | 140NOC78100 |
6DR2004-1A | TM0180-05-05-03-10-02 | 140NOE77101 |
6DR2100-4 | TM0180-A08-B00-C12-D10 | 140NOE77110 |
6DR2100-5 | TM0180-A08-B00-C15-D10 | 140NOE77111 |
6DR2104-4 | TM0180-A08-B13-C20-D10 | 140NOM21100 |
6DR2104-5 | TM0181-A40-B01 | 140NOM21200 |
6DR2410-5 | TM0182 TM0182-A50-B01-C00 | 170ADO35000 |
353A4F1NNNTNNA4 | TM0182-A90-B01-C00 | 170INT11003 |
353D4F1NNETNNA4 | 57C404C | 416NHM30032 |
383VA21N1F | 57C405-E | 990NAD21110 |
39ACM14CAN | 586-501-109 M20010003401 | 990XCP98000 |
39PSMNAN | TH-N12TP | AM-SA85-000 |
39PSR4ANDN 16114-200/01 | SRB-NA-R-C.35/CH2A-24V | AS-P890-000 |
39RTMCAN | 140ACI03000 | AS-S908-110 |
39VIMCBN | 140ACI04000 | ATV61HD37N4 |
39VIMCCN | 140ACI05100SC | LXM15MD28N4 |
39VIMNBN | 140ACO02000 | ME4U07AAA |
3RX9306-1AA00 | 140ACO13000 | NWBM85C002 BM85C002 |
3BHE024577R0101 PP C907 BE | 140ARI03010 | TSX3721001 |
Product's Character:
The procedure is repeated for the other input and output channels with each successive pressing and releasing of the test button. After accessing the last channel, another pressing of the test botton initiates an LED test. All LEDs must light up. Following that, the position of the address switch is displayed
by LEDs 00 to 07 for about 3 seconds which was set by module 07 DC 92 during the initialization. In this
case LED 00 shows the setting of switch 1 (LEDs 0...7 are assigned to switches 1...8 ).The error messages at the I/O module and at the central control unit go out as soon as the errors have been corrected, no new errors exist and the error correction has been acknowledged.
The use of the product:
2. water, water treatment / environmental protection,
1. Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )