Differential inputs are very useful, if analog sensors are used which are remotely non-isolated (e.g. the minus terminal is remotely earthed). Since the earthing potential is not exactly the same as
AGND1, it has to be measured bipolar in order to compensate measuring errors. Additionally, in case of singlepole configuration, AGND1 would be connected directly to the remote earth potential. This would cause inadmissable (and possibly dangerous) earthing loops. In all configurations using differential inputs two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). The measured value is calculated by subtraction. The value of the channel with the lower address is subtracted from the value of the channel with the higher address.
Related Product Recommendation:
9300-4EDM | SCC-F 23212-0-110310 | 140CRA31200 |
AT-PWR4 | SD812V1 | 140CRA93100 |
PD-4B PD4B | SDCS-CON-2A ADT309600R0002 | 140CRP31200 |
MMLG01 | SDCS-IOB-22 3BSE005177R1 | 140CRP93100 |
0190-26769 | SDCS-IOB-3 3BSE004086R1 | 140DAI55300 |
AMCI 1531 | SNAT 609 SNAT 609 TAI | 140DAI74000 |
AMCI 1642 | SNAT 609 SNAT609 | 140DAO84000 |
AMCI 8213 | SNAT 7261 | 140DAO85300 |
AMCI SD17060B-25 | SNAT0100-6B SNAT 0100-6B 61054588 5761852-3B | 140DDI35300 |
AMCI SD3520 | SNAT601TAI | 140DDI35310 |
DNC-T2010-R20 | SNAT603CNT SNAT 603 CNT | 140DDO35300 |
AMK MIFA M2 41961-9111-003023 | 6ES5526-3LG0 | 140DDO35301 |
KL2300A | 6ES5535-3LB12 | 140DDO35310 |
AB-7007-C | 6ES5927-3SA12 | 140DDO36400 |
MAC-B343-GM60 | AS-B805-016 | 140NOC78000 |
PS-3306D-E | AS-J890-101 | 140NOC78100 |
PCI2000PFB | TM0180-05-05-03-10-02 | 140NOE77101 |
0190-26769 | TM0180-A08-B00-C12-D10 | 140NOE77110 |
GMSV36-01-D 91/096D/E | TM0180-A08-B00-C15-D10 | 140NOE77111 |
SE-WLS220-2.1/05 | TM0180-A08-B13-C20-D10 | 140NOM21100 |
ARCHIVE 2150S | TM0181-A40-B01 | 140NOM21200 |
YXO124 4890024-LF | TM0182 TM0182-A50-B01-C00 | 170ADO35000 |
YXO126 4890024-UN YXO 126 | TM0182-A90-B01-C00 | 170INT11003 |
XN03 XN 03 | 57C404C | 416NHM30032 |
XN05 XN 05 | 57C405-E | 990NAD21110 |
XN06 XN 06 | 586-501-109 M20010003401 | 990XCP98000 |
XO08R1 XOO8R1-B04 1SBP260101R1001 | TH-N12TP | AM-SA85-000 |
Product's Character:
The converted measured value is available on the odd address (e.g. EW 6,01). Important: The common mode input voltage range equals the measuring range of the single channel. I.e. that the signals,
related to AGND, at the two involved inputs must not exceed this measuring range. Input voltages which exceed the measuring range cause an overflow error message. If the measured value is below
the range, an underflow error message is generated.
The use of the product:
1.Avoid unplanned downtime
2. new and original
3.1 year warranty
1.Q:How about the payment terms ?
A:We frequently use T/T
2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )