Temperatures which exceed the measuring range cause an overflow error message. If the measured value is below the range, an underflow error message is generated. A detected open-circuit causes an overflow error message. If the sensor is short-circuited, an underflow error message is generated.
If the open-circuit or short-circuit monitoring is configured, the detected error is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9).
In order to avoid error messages with unused analog inputs, it is useful, not to configure this channels for Pt100.
Related Product Recommendation:
8-061588-002 I/O | SCC-F 23212-0-110310 | 140CRA31200 |
SB1381-B-E-R-A-PM2 | SD812V1 | 140CRA93100 |
SB1381-C-E-R-A | SDCS-CON-2A ADT309600R0002 | 140CRP31200 |
HSSI-I016 | SDCS-IOB-22 3BSE005177R1 | 140CRP93100 |
NPSA-TMTA-222 | SDCS-IOB-3 3BSE004086R1 | 140DAI55300 |
ADEPT AWCII 040 | SNAT 609 SNAT 609 TAI | 140DAI74000 |
AWCII-040 | SNAT 609 SNAT609 | 140DAO84000 |
NS700 024 13NS700024/2W | SNAT 7261 | 140DAO85300 |
BLF-022828 ACC-BOARD | SNAT0100-6B SNAT 0100-6B 61054588 5761852-3B | 140DDI35300 |
BLG-022829 | SNAT601TAI | 140DDI35310 |
R6244 | SNAT603CNT SNAT 603 CNT | 140DDO35300 |
OR4000T | 6ES5526-3LG0 | 140DDO35301 |
KL2300A | 6ES5535-3LB12 | 140DDO35310 |
AB-7007-C | 6ES5927-3SA12 | 140DDO36400 |
MAC-B343-GM60 | AS-B805-016 | 140NOC78000 |
PS-3306D-E | AS-J890-101 | 140NOC78100 |
PCI2000PFB | TM0180-05-05-03-10-02 | 140NOE77101 |
0190-26769 | TM0180-A08-B00-C12-D10 | 140NOE77110 |
GMSV36-01-D 91/096D/E | TM0180-A08-B00-C15-D10 | 140NOE77111 |
SE-WLS220-2.1/05 | TM0180-A08-B13-C20-D10 | 140NOM21100 |
ARCHIVE 2150S | TM0181-A40-B01 | 140NOM21200 |
YXO124 4890024-LF | TM0182 TM0182-A50-B01-C00 | 170ADO35000 |
YXO126 4890024-UN YXO 126 | TM0182-A90-B01-C00 | 170INT11003 |
XN03 XN 03 | 57C404C | 416NHM30032 |
XN05 XN 05 | 57C405-E | 990NAD21110 |
XN06 XN 06 | 586-501-109 M20010003401 | 990XCP98000 |
XO08R1 XOO8R1-B04 1SBP260101R1001 | TH-N12TP | AM-SA85-000 |
Product's Character:
In the operating mode "Pt100 in 3-wire configuration" two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured to the desired operating mode.The constant current of the one channel flows through the Pt100 resistance sensor, the constant current of the other channel through one of the wires. The basic unit calculates the measuring value from the two voltage drops and stores it under the odd address (e.g. EW 6,01).In order to avoid measurement errors, it is absolutely necessary,to lead the cores to the Pt100 sensors in the same cable. The cores must have the same cross section. Per channel, a twisted pair is used (for the two terminals of
the Pt100 sensors) plus a single core (half of a twisted pair) for the connection to AGND1.
The use of the product:
1.textile printing and dyeing,
2. new and original
3.1 year warranty
1.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )