In the central units 07 KR 91 / 07 KT 9x, the errors are displayed as follows: Out of range
Error classification 4 (FK4) M 255.14 Error recognition: 10 dec. -> MW 255.08 Module type: * 01/03/05 -> MW 255.09 Group number: -> MW 255.10 Channel number: -> MW 255.11 In the initial state after initialization, channel 0 is selected and the corresponding analog value ist displayed (see also
figures Diagnosis functions can be selected individually for each channel with the test button. The initial actuation of the test button selects channel 0. The diagnosis LEDs 0 to 3 display the channel number in hexadecimal code.
Related Product Recommendation:
BRC300 PHCBRC30000000 | CM30/000S0E0/STD | SNAT633PAC |
C100/0100/STD | CMA112 3DDE300013 | SNAT7780 |
C1900/0263/0260A C1900/0263 | CMA114 3DDE300013 | SPGU240A1 SPGU 240 A1 |
C1900/0363 C1900/0363/0360A | CMA121 3DDE300401 | SPNPM22 |
C300/0010/STD | CMA132 3DDE300412 | TC520 3BSE001449R1 |
CI520V1 3BSE012869R1 | CS300E PAC 031-1053-00 | TP830 3BSE018114R1 |
CI522 3BSE012790R1 | CS513 3BSE000435R1 | TPC-1570H 3BHE031734R1011 |
CI522A 3BSE018283R1 | D0910S | TU830V1 |
CI526 3BSE006085R1 | DAI01 | VV01 VV 01 |
CI531 3BSE003825R1 | DAI04 | VV11 VV 11 |
CI532V01 3BSE003826R1 | PM630 3BSE000434R1 | WT98 07KT98 |
07PS62R2 GJV3074332R2 | PM632 3BSE005831R1 | XI16E1 1SBP260100R1001 |
07SK90R1 GJR5250200R0001 | PM633 3BSE008062R1 | XM02 XM 02 |
07ZE61R302 GJV3074321R302 | PM645C 3BSE010537R1 | XM03 XM 03 |
INICT03A | PM810V2 3BSE013220R1 | XM06B5 1SBP260103R1001 |
INIIT13 | PM860K01 3BSE018100R1 | XN03 XN 03 |
INNPM22 | PM861AK01 3BSE018157R1 | XN05 XN 05 |
LL02 LL 02 | PP835A 3BSE042234R2 | XN06 XN 06 |
LZ01 LZ 01 | PU513V2 3BSE013034R1 | XO08R1 XOO8R1-B04 |
LZ02 LZ 02 | PU514 3BSE013062R1 | XP01 XP 01 |
MA01 MA 01 | PU515A 3BSE032401R1 | XU03 XU 03 |
MA03 MA 03 | RDCU-02C | XU04 XU 04 |
MA12 MA 12 | REF610 | XV371A |
MAG-XE | REF615 | YPH107A 3ASD573001A9 |
MAI32MAD | RF616 3BSE010997R1 | YPH108B/SPC |
MB21 MB 21 | RL01 RL 01 | YPK113A 5761857-4A |
1700RZ10005C | 200-CICN 200-CIE | 3ASC25H705/7 |
Product's Character:
The error messages on the module and on the central unit go out again as soon as the error has been corrected, no new errors have been recognized and the error correction was acknowledged.
Acknowledging an error after error correction: by pressing the test button for about 5 seconds, or with the PC, or with the PLC program in the central unit The current input has a self-protecting feature for the
measuring range 0...20 mA. If the current gets too high, the current input shunt is switched off and the value for "overflow" is output. Re-activation is attempted again in increments of approx. 1 second to facilitate the correct measurement as soon as the current regains acceptable limits.
The use of the product:
1. Provides the lowest Total Cost of Ownership (TCO)
2. new and original
3.1 year warranty
1.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )