ABB Module SAFT185TBC SAFT 185 TBC 58119687 ABB SAFT185TBC CONTROL BOARD MODULE supply to worldwide
Product Description:
If the open-circuit or short-circuit monitoring is configured, the detected error is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9).
In order to avoid error messages with unused analog inputs, it is useful, not to configure this channels for Pt100. Connection of Pt100 temperature sensors in 3-wire configuration If the sensors are located close together, only one core is needed as
the return wire AGND1. In the operating mode "Pt100 in 3-wire configuration" two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured to the
desired operating mode, see configuration table Fig. The constant current of the one channel flows through the Pt100 resistance sensor, the constant current of the other channel through one of the wires.
The basic unit 07 KT 94 calculates the measuring value from the two voltage drops and stores it under the odd address
Related Product Recommendation:
PDS01 | MZ01 | DSQC227 YB560103-CE |
PDV01 | MZ03 | DSQC223 YB560103-CD |
PE01 | DPW02 | DSQC205 YB560103-BK |
PEA01 | DRA02 | DSQC201 YB560103-BD |
PEA02 | EP07 | DSQC104 YB560103-AD/1 |
PEA03 | HA01 | DSQC 633A YB560103-AB |
PEB02 | HA02 | DSQC 539 6369901-104 |
PEB03 | HH01 | DSQC 352A 3HAC 031851-001 |
PGM01 | HH03 | DSSR170 48990001-PC 3HAC14265-1 |
LL02 | HH04 | DSSB146 |
LL03 | HH11 | DSTD150A 48980001-AP/1 DSSB146*BAT2C |
LM01 | HM01 | DSTD132 |
LM21 | HM11 | DSTD108P 57160001-UH |
LT02 | HM21 | DSTD108 5716001-FX |
LZ01 | HP01 | DSTD 110A 3BSE018333R1 |
LZ02 | HP03 | DSTC454 5751017-F 57160001-ABD/ABW |
MA01 | HP21 | DSTC190 57520001-ER 57160001-TZ |
MA02 | HS01 | DSTA180 |
MA03 | HS11 | DSTA160 |
MA12 | HV01 | DSTA131 57120001-CV 57120001-ET |
MB01 | HV12 | DSTA131 57120001-AH |
MB02 | HW81 | DATX130 3ASC25H214 57120001-CV |
MB11 | HW91 | DAPC100 |
MB12 | LL01 | DAI05 3ASC25H203 |
MB21 | AV02 | DAI03 P37131-4-0336025 |
MR01 | AV05 | DCP02 |
MS01 | AV06 | 3ASU21C110 LU6278 DCU30/7 P-37211-4-0369654 |
Product's Character:
IResolution in the PLC system: The measured values are converted with a resolution of
12 bits, i.e. 11 bits plus sign for voltage and 12 bits without sign for current. The ranges 0...5 V und ±5 V are converted with 10 bits plus sign.the output A 62,00 is only available for the counter. If the output is to use as a normal digital output, it has to Further details can be found in volume 2, chapter 5.1 "General
information for the use of analog inputs and outputs". In order to make sure, that unused input channels have a defined 0V level, they may be shorted to AGND. Unused inputs must be configured with "unused".
The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows
DSAI130 57120001-P DSAI 130 Analog Input Module ABB
DSAI130A 3BSE018292R1 DSAI 130A Analog Input Module ABB
DSAI145 5712001-HA RTD Input Module ABB
DSAI146 3BSE007949R1 RTD Input Module ABB
DSAI155 57120001-HZ Thermocouple Module ABB
DSAI155A 3BSE014162R1 Thermocouple Module ABB
DSAI303 57120001-CL Analog Input Board ABB
DSAI305 57120001-BX/3 Analog Input Board ABB
DSAO 110 57120001-AT Analog Output Module ABB
DSAO 130 57120001-FG DSAO130 Analog Output Board 16 Channels ABB
DSAO120 57120001-EY DSAO 120 Analog Output Module 8 Channels ABB
DSAO120A 3BSE018293R1 Analog Output Board ABB
DSAO301 57120001-DZ/4 Analog Output Board ABB
DSAV110 57350001-E Driver Module Video ABB
DSAV111 57350001-CN DSAV 111 Video Generator Module ABB
DSAX110 57120001-PC/5, 57120001-PC/6 DSAX 110 Analog Input/Output Module ABB
DSAX110A 3BSE018291R1 DSAX 110A Analog Input/Output Module ABB
DSAX452 5712289-A DSAX 452 BasicUnit - Analog I/O ABB
DSBB102 57310256-A / 1 Busboard MV 850 ABB
DSBB107 57310256-BE Bus Board ABB
DSBB110 57330001E ABB Master Shield Board ABB
DSBB110A 57330001-Y ABB Master Shield Module ABB
DSBB120 4898 0002-A Battery Backup Unit ABB
DSBB170 57310256-DL Bus Board ABB
DSBB175 57310256-CC/I Bus Board ABB
DSBBN001-0 Back Plane ABB
DSBBN002-0 Back Plane ABB
DSBC110 57310256-E/1 DSBC 110 Bus Termination Module ABB
DSBC111 57310256-K/1 DSBC 111 Bus Module ABB
DSBC170 57310256-DB Bus Module ABB
DSBC172 57310001-KD/5, 57310001-KD DSBC172 Bus Repeater Module ABB
DSBC172N 3BNP000467R1 Repeater Module ABB
DSBC173 57310001-KH DSBC 173 Bus Extender S100 I/O Bus ABB
DSBC173A 3BSE005883R1 Bus Extender S100 I/O Bus ABB
DSBC173N 3BNP000468R1 Repeater Module ABB
DSBC174 3BSE012211R1 DSBC 174 Bus Extender Module - S100 I/O Bus ABB
DSBC176 3BSE019216R1 Bus Extender Board ABB
DSBSN001 Digital Output Board ABB
DSCA114 57510001-AA DSCA 114 Communication Board ABB
DSCA124 57520001-BU Communications Module ABB
The use of the product:
1.Optimize plant operations
2.emission reduction
3.Avoid unplanned downtime
1.Provides the lowest Total Cost of Ownership (TCO)
2.emission reduction
3.Avoid unplanned downtime
1.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
2.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could
promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )