ABB Module XI16E1 1SBP260100R1001 ABB XI16E1 Binary Inputs New spot folding
Product Description:
In order to avoid measurement errors, it is absolutely necessary, to lead the cores to the Pt100 sensors in the same cable. The cores must have the same cross section. Per channel, a twisted pair is used (for the two terminals of the Pt100 sensors) plus a single core (half of a twisted pair) for the connection to AGND1. Depending on the configured operating mode, the measured value is assigned linearly as follows the return wire AGND1. In the operating mode "Pt100 in 3-wire configuration" two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured to the desired operating mode, see configuration table Fig. The constant current of the one channel flows through the Pt100 resistance sensor, the constant current of the other channel through one of the wires.
The basic unit 07 KT 94 calculates the measuring value from the two voltage drops and stores it under the odd address
Related Product Recommendation:
3BSE055760R1 | VV03 | DAO01 |
3BHT300012R1 | VV11 | DCO01 |
3BHT00006R1 | XB01 | DCP02 |
3BHT300007R1 | XI01 | PAA02 |
57120001-PS | XI91 | PAB02 |
57120001-DP | XK11 | PAR01 |
57120001-P | XK12 | DDO02 |
5712001-HA | XK15 | XN05 |
3BSE007949R1 | XK16 | XN06 |
57120001-HZ | XM01 | XP01 |
3BSE014162R1 | XM02 | XU01 |
57120001-AT | XM03 | XU02 |
57120001-FG | XN01 | XU03 |
57120001-EY | XN03 | XU04 |
3BSE018293R1 | PGM03 | XU12 |
57120001-PC/5, 57120001-PC/6 | PGM09 | XU13 |
3BSE018291R1 | PGM35 | XU14 |
4898 0002-A | PGM48 | XX02 |
57310001-KD/5 | PMK24 | SS25 |
57310001-KH | DFC01 | SS41 |
3BSE005883R1 | DFE01 | SV01 |
3BSE012211R1 | DFI01 | TET106 |
57520001-EV | DFM11 | TET106-EX.D |
57160001-A/13,57160001-A | DFP01 | TEU315-EX.B |
57160001-AAA | DLM01 | TEU320 |
57160001-AK | DPW01 | TEU325-EX.B |
57160001-K | DCP10 | TEU411 |
Product's Character:
Use of analog inputs as digital inputs Several (or all) analog inputs can be configured as digital inputs. When doing so, they evaluate input voltages higher than ca. +7 V as signal 1. The input impedance in this
operating mode is about 4 kW. Terminal M is the reference potential. The input signal delay is 7 ms. It cannot be configured. The inputs are not electrically isolated. they may be shorted to AGND. Unused inputs must be configured with "unused". The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows
DO0116 FDO0116 Digital Output Module Bailey
DO210 492953501 Digital Output Module ABB
DO610 3BHT00006R1 Digital Output Module ABB
DO620 3BHT300009R1 DO620 Digital Output Module ABB
DO630 3BHT300007R1 Digital Output Module ABB
DO801 3BSE020510R1 S800L DO801 Digital Output ABB
DO802 3BSE022364R1 S800L DO802 Digital Output, Relay. ABB
DO810 3BSE008510R1 DO810 Digital Output Module ABB
DO814 3BUR001455R1 DO814 Digital Output Module ABB
DO815 3BSE013258R1 Digital Output Module - 24Vdc ABB
DO820 3BSE008514R1 Digital Output Relay Module - N.O. ABB
DO821 3BSE013250R1 Digital Output Module - Relay ABB
DO840 3BSE020838R1 Digital Output Module ABB
DO86-16 57275758 Digital Output Module ABB
DO880 3BSE028602R1 Digital Output Module ABB
DO890 3BSC690074R1 DO890 Digital Output w/ Intrinsic Safety Interface ABB
DO910S 3KDE175321L9100 Digital Output Module ABB
DO930N 3BDS014114 Relay Output Module ABB
DOC-01 Output Module ABB
DOT100 PHBDOT10010000 DOT-100 Digital Output Block ABB
DOT120 PHBDOT12010000 Digital Output Module ABB
DP640 3BHT300057R0001 DP640 Speed Measurement Module ABB
DP820 3BSE013228R1 Pulse Counter ABB
DP840 3BSE028926R1 Pulse Counter or Frequency Measurement Module ABB
DPW 01 P3761158018181, 8018181M DPW01 Power Supply ABB
DPW 02 Power Supply - 24 Vdc Input ABB
DPW03 P37611-5-8018644, 8018544M DPW 03 Power Supply Module ABB
DRA 02 37411-4-0369673 DRA 02 Card Rack ABB
DRA 03 0369674M DRA 03 Freelance Rack, 3 Slot ABB
DRA 04 0369675M DRA 04 Freelance Rack, 5 Slot ABB
DSAI 133 57120001-PS Analog Input Board 32 Channels ABB
DSAI 133N 3BSE018526R1 Analog Input Module ABB
DSAI110 57120001-DP DSAI 110 Analog Input Module ABB
The use of the product:
1.Optimize plant operations
2. new and original
3.1 year warranty
Our advantages:
1.365 days warranty for all the goods from us.
2.emission reduction
3.Avoid unplanned downtime
1. Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Contact Us at Any Time