Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > ABB Module >
ABB Module YXT115B 4890024-NK ABB YXT115B 4890024NK GIULIETTA SPIDER High quality
  • ABB Module YXT115B 4890024-NK ABB YXT115B 4890024NK   GIULIETTA SPIDER  High quality

ABB Module YXT115B 4890024-NK ABB YXT115B 4890024NK GIULIETTA SPIDER High quality

Place of Origin Sweden
Brand Name ABB Module
Certification CO.CQ
Model Number YXT115B 4890024-NK
Product Details
Manufacture Year:
2016
Control System:
ABB Module System
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
YXT115B 4890024-NK ABB YXT115B 4890024NK GIULIETTA SPIDER
Weight:
4lbs
High Light: 

advant ocs

,

advant controller 31

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

ABB Module YXT115B 4890024-NK ABB YXT115B 4890024NK GIULIETTA SPIDER High quality

 

Product Description:

 

IResolution in the PLC system: The measured values are converted with a resolution of
12 bits, i.e. 11 bits plus sign for voltage and 12 bits without sign for current. The ranges 0...5 V und ±5 V are converted with 10 bits plus sign.the output A 62,00 is only available for the counter. If the output is to use as a normal digital output, it has to Further details can be found in volume 2, chapter 5.1 "General
information for the use of analog inputs and outputs". In order to make sure, that unused input channels have a defined 0V level, they may be shorted to AGND. Unused inputs must be configured with "unused".
The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows

 

 

 

ABB Module YXT115B 4890024-NK ABB YXT115B 4890024NK   GIULIETTA SPIDER  High quality 0

 

Related Product Recommendation:

 

XN01   MB21 3ASC25H705/7
XN03   MR01 3ASU21C110 LU6278 DCU30/7
PGM03   MS01 3AUA489002B4562
PGM09   MT01 3BHE022291R0101 PCD230A
PGM35   MV01 3BHE023784R2530 PP D113
PGM48   MV03 3BHE024577R0101 PP C907 BE
PMK24   MZ01 3BSE001245R1 3BSC640008R1
DFC01   MZ03 3BSE003879R1
DFE01   DPW02 3BSE011316R1 SDCS-PIN-52
DFI01   DRA02 3HAC14550-4
DFM11   EP07 3HAC14551-2
DFP01   HA01 3HAC17484-8
DLM01   HA02 3HAC17484-9
DPW01   HH01 3HNE00313-1
DCP10   HH03 3HNM09846-1
DDI01   HH04 3HNP04014-1
DDO01   HH11 424K1105
07KR264dR1   HM01 6638910B1 638910B1PS0084
07KR220dR1   HM11 7944831D
07KR228d   HM21 89AR30
07KR240R2   HP01 A8PU05ABFW02
IV0790   HP03 AI610 3BHT300000R1
07SK90R1 GJR5250200R0001   HP21 AI625 3BHT300036R1
GJR5251600R0202 07AI91C   HS01 AI630 3BHT300011R1
GJR5253200R1161   HS11 AI810 3BSE008516R1
23WT90RTU510   HV01 AI830A 3BSE040662R1
07KR51 07KR51-U3.6   HV12 AV31 AV 31
07 KR 51-P30; 07 KR 51-F12   HW81 AV43 AV 43
07KT51 07KT51-U3.6   HW91 AX460
XM03   LL01 AX521 1SAP250100R0001
PVM04   AV02 AX645 3BHB001914R1
086363-002 OSPS2   AV05 BRC-100 P-HC-BRC-10000000


Product's Character:

 

In case of a configured plausibility monitoring, range underflow and range overflow by 2...3 % result in an error message (FK4, error number 10). Independent of the configured monitoring, the error values +32767 and -32767 are always generated in case of range underflow and range overflow. Exception: In the measuring range of 0...20 mA only the range overflow is Unused inputs must be configured with "unused". The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows

 

 

 

 

ABB Module YXT115B 4890024-NK ABB YXT115B 4890024NK   GIULIETTA SPIDER  High quality 1

 

 

FPR3330705R0321 ICBG32L7 Robot Coupler ABB
FPR3330705R0641 ICBG32L7 Robot Coupler ABB
FPR3331001R1202 ICSK20N1 I/O Remote Unit ABB Module ABB
FPR3331001R1204 ICSK20N1 I/O Remote Unit Module ABB
FPR3331001R1206 ICSK20N1 I/O Remote Unit Module ABB
FPR3335801R1012 ICST08A8 Analog Input Module - RTD ABB
FPR3335801R1014 ICST08A8 Analog Input Module - RTD ABB
FPR3335801R1016 ICST08A8 Analog Input Module - RTD ABB
FPR3335901R1012 ICST08A9 Analog Input Module - RTD ABB
FPR3335901R1014 ICST08A9 Analog Input Module - RTD ABB
FPR3335901R1016 ICST08A9 Analog Input Module - RTD ABB
FPR3341501R0044 ICSA04B5-120 Analog Output Unit - 120 V ABB
FPR3341501R0046 ICSA04B5-230 Analog Output Unit - 230 V ABB
FPR3341501R1042 ICSA04B5-24 Analog Output Unit - 24 Vdc ABB
FPR3345601R1012 ICSE08A6 Remote Analog Input Module ABB
FPR3345601R1014 ICSE08A6 Remote Analog Input Module ABB
FPR3345601R1016 ICSE08A6 Remote Analog Input Module ABB
FPR3346501R0014 ICSE08B5 Analog Input Remote Unit -120 VAC ABB
FPR3346501R0016 ICSE08B5 Analog Input Remote Unit 230 VAC ABB
FPR3346501R1012 ICSE 08 B5, ICSE08B5-24. ICSE08B5 Remote Analog Unit - 24 VDC ABB
FPR3350601R0064 ICSM06A6 Analog I/O Remote Unit ABB
FPR3350601R0066 ICSM06A6 Analog I/O Remote Unit ABB
FPR3350601R1062 ICSM06A6 Analog I/O Remote Unit ABB
FPR3471200R0006 NCB NCB Bus Amplifier ABB
FPR3471200R1002 CS31 Buss Repeater ABB
FPR3471300R0006 NCB NCB Bus Amplifier - Redundancy ABB
FPR3471300R1002 CS31-Repeater RS485 Module ABB
FPR3600201R0206 PLC Module ABB
FPR3600201R1202 PCZB PCZB Module ABB
FPR3600227R0204 07KR31 07 KR 31 Central Processing Unit -120 Vac ABB

FPR3600227R0206 07KR31 07 KR 31 Central Processing Unit- 230 vac ABB
FPR3600227R1202 07KR31 07 KR 31 Central Processing Unit 24VDC Input Power

 

The use of the product:

 
1.energy,

2.boiler Heating,

3. chemical,
 
Product's advantages:
 

1.Experienced technichal support team.

 

2. new and original


3.1 year warranty

 

Our advantages:

 

1.365 days warranty for all the goods from us.


2.emission reduction


3.Avoid unplanned downtime

 
Frequently Asked Questions:
 

1. Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.

 

2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.

 

3. Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
 
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us