ABB Module DSTA131 57120001-CV 57120001-ET ABB DSTA131 CONNECTION UNIT DRIVE Performance great
Product Description:
When resistance thermometers are used, a constant current must flow through the measuring resistor in order to create the necessary voltage drop for the evaluation. For this purpose, the basic unit 07 KT 94 provides a constant current sink, which is multiplexed to the 8 analog channels. The following figure shows the connection of Pt100 resistance thermometers in 2-wire configuration.Measuring ranges and with Pt100 as temperature sensor in 3-wire configuration The following figure shows the connection of Pt100 resistance thermometers in 3-wire configuration.The 07 KT 94 unit linearizes the Pt100 characteristic.Temperatures that exceed the measuring range cause the overflow numerical value of +32767. If the measured value is below the range, the underflow numerical value of -32767 is set. In case of a detected open-circuit the numerical value of +32767 is set. If the sensor is short-circuited, the numerical value of -32767 is set.
Related Product Recommendation:
07KT98 GJR5253100R0270 | CS513 3BSE000435R1 | 07KT97B |
07KT98 WT98 | D0910S | 07KT97C |
07MK92 GATS110098R0161 | DAI01 | 07KT97 |
07MK92 GJR5253300R1161 | DAI04 | 07KT97B |
07NG61R1 GJV3074311R1 | DAO01 | 07KT97B |
07NG63R1 GJV3074313R1 | DAPC100 3ASC25H203 | 07KT97B |
07PS62R2 GJV3074332R2 | DAPC100 3ASC25H203 | 07KT97B |
07SK90R1 GJR5250200R0001 | DAPU100 3ASC25H204 | 07KT98E2 |
07ZE61R302 GJV3074321R302 | DATX110 3ASC25H209 | 07MK92 |
07ZE63R302 GJV3074323R302 | DATX130 3ASC25H214 | TC50 |
086363-002 OSPS2 | DATX132 3ASC25H216 | ICFC16l1 |
1700RZ10005C | DCF503-0050 | ICSF08D1 |
1SAR330020R0000 | DCP02 P-37211-4-0369654 | ICSK20F1-120 |
200-CICN 200-CIE | DCP10 | ICSK20F1-230 |
2012AZ10101B | DDI01 | ICSK20F1-24 |
35AE92A ER0002081060005 | DDO01 | ICSK20N1 |
3ASC25H705/7 | DI685 3BDS005833R1 | ICSA04B5 |
3ASU21C110 LU6278 DCU30/7 | DI811 3BSE008552R1 | ICSE08B5 |
3AUA489002B4562 | DIGITRIC 500 61615-0-1200000 | 07KR31 |
3BHE022291R0101 PCD230A PC D230 A | DLM01 | 07KR31 |
3BHE023784R2530 PP D113 B01-25-111000 | DLM02 | 07KT31 |
3BHE024577R0101 PP C907 BE | 07KR91 | 07MK62 |
3BSE001245R1 3BSC640008R1 | 07KR91 | 35NE90 |
3BSE003879R1 | 07KT92 | 35GS91 |
3BSE011316R1 SDCS-PIN-52 | 07KT92 | 35GS91 |
3HAC14550-4 | 07KT92 | 35DS91 |
PCZ25 | 07KP90 | 35AB94B |
PCZ28 | 07KT93 | 35AA92C-E |
PDD02 | 07KT93 | 35EK90 |
PDK01 | 07KT93 | 35EK91 |
07SK90R1 GJR5250200R0001 | ICDG32L1 | 35TP90 |
Product's Character:
In order to avoid measurement errors, it is absolutely necessary, to lead the cores to the Pt100 sensors in the same cable. The cores must have the same cross section. Per channel, a twisted pair is used (for the two terminals of the Pt100 sensors) plus a single core (half of a twisted pair) for the connection to AGND1. Depending on the configured operating mode, the measured value is assigned linearly as follows the return wire AGND1. In the operating mode "Pt100 in 3-wire configuration" two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured to the desired operating mode, see configuration table Fig. The constant current of the one channel flows through the Pt100 resistance sensor, the constant current of the other channel through one of the wires.
The basic unit 07 KT 94 calculates the measuring value from the two voltage drops and stores it under the odd address
DCS800-EP2-0230-05 Module Drive ABB
DCS800-EP2-0315-05 Module Drive ABB
DCS800-EP2-0405-05 Module Drive ABB
DCS800-EP2-0470-05 Module Drive ABB
DCS800-EP2-0610-05 Module Drive ABB
DCS800-PAN Field Kit ABB
DCS800-S01-0020-05 Module Drive ABB
DCS800-S01-0045-05 Module Drive ABB
DCS800-S01-0065-05 Module Drive ABB
DCS800-S01-0090-05 Module Drive ABB
DCS800-S01-0125-05 Module Drive ABB
DCS800-S01-0180-05 Module Drive ABB
DCS800-S01-0230-05 Module Drive ABB
DCS800-S01-0290-06 Module Drive ABB
DCS800-S01-0290-07 Module Drive ABB
DCS800-S01-0315-05 Module Drive ABB
DCS800-S01-0405-05 Module Drive ABB
DCS800-S01-0470-05 Module Drive ABB
DCS800-S01-0900-06 Module Drive ABB
DCS800-S01-0900-07 Module Drive ABB
DCS800-S01-1500-06 Module Drive ABB
DCS800-S01-1500-07 Module Drive ABB
DCS800-S01-2050-05 Module Drive ABB
DCS800-S01-2050-06 Module Drive ABB
DCS800-S02-0025-05 Module Drive ABB
DCS800-S02-0050-05 Module Drive ABB
DCS800-S02-0075-05 Module Drive ABB
DCS800-S02-0100-05 Module Drive ABB
DCS800-S02-0140-05 Module Drive ABB
DCS800-S02-0200-05 Module Drive ABB
DCS800-S02-0260-05 Module Drive ABB
DCS800-S02-0290-06 Module Drive ABB
DCS800-S02-0290-07 Module Drive ABB
DCS800-S02-0350-05 Module Drive ABB
DCS800-S02-0450-05 Module Drive ABB
DCS800-S02-0520-05 Module Drive ABB
The use of the product:
1. Provides the lowest Total Cost of Ownership (TCO)
2. new and original
3.1 year warranty
Our advantages:
1.Optimize plant operations
2.emission reduction
3.Avoid unplanned downtime
1.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
2.Q:How about the payment terms ?
A:We frequently use T/T
3.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )