Allen Bradley Modules 1361-NO61-2-5 1361NO6125 AB 1361-NO61-2-5 REBUILT CYLINDER superior quality product
Product Description:
The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.). The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix this point, I/O between the ControlLogix processor and the 1203- CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please ontact technical support.
Related Product Recommendation:
1756-IF8H | 1785-L60L | 1771-DB |
1756-IH16I | 1785-L80B | 1771-DXPS |
1756-IM16I | 1785-L80C | 1771-HS3A |
1756-IR6I | 1785-L80C15 | 1771-IAD |
1756-IT6I | 1785-LT3 | 1771-IAN |
1756-IT6I2 | 1785-LTB | 1771-IB |
1756-IV16 | 1785-ME16 | 1771-IFEK |
1756-IV32 | 1785-ME32 | 1771-IFM |
1756-L1 | 1785-PFB | 1771-IK |
1756-L1M2 | 1785-V40L | 1771-IL |
1756-L1M3 | 1785-V40V | 1771-IR |
1756-L55 | 1785-V80B | 1771-NC15 |
1756-L55M12 | 1786-BNC | 1771-NC6 |
1756-L55M13 | 1786-RPA | 1771-NIS |
1756-L55M14 | 1786-RPFM | 1771-NR |
1756-L55M16 | 1786-RPFRL | 1771-OBD |
1756-L55M22 | 1786-RPFRXL | 1771-OQ16 |
1756-L55M23 | 1788-CN2FF | 1771-OW16 |
1756-L55M24 | 1788-CNC | 1771-OZL |
1756-L60M03SE | 1788-CNET | 1771-P4R |
1756-L61 | 1788-ENBT | 1771-P7 |
1756-L61S | 1790D-TN4V0 | 1771-SDN |
1756-IF6CIS | 1785-ENET | 1772-LN2 |
1756-IF6I | 1785-L20B | 1772-LS |
150-SD1NBR | 1785-L20C | 1772-LW |
150-SD1NUD | 1442-PS-0512M0010A | 1747-AIC |
150-SD1NUR | 1442-PS-0512M0010N | 1747-AICR |
150-SD2NBD | 1442-PS-0515M0010A | 1747-ASB |
150-SD2NBR | 1442-PS-0515M0010N | 1747-BA |
150-SD2NUD | 1442-PS-0516E0010A | 1747-DCM |
150-SD2NUR | 1442-PS-0516E0010N | 1747-KE |
Product's Character:
Appendix B provides information about the Block Transfer messages supported by
the Remote I/O communications module. In this appendix, you will read about the
following: Block transfer status word.
Setting up data files for block transfer messages.Examples of block transfer
messages. Block transfer quick reference. Important: This appendix provides
detailed examples of block transfer messages. For information about block
transfer messages, also refer to Chapter 5.Chapter 1 provides an overview of the
Remote I/O communications module (1203-GD1 module, 1203-GK1 module, and 1336-GM1
board). In this chapter, you will read about the following:Function of the
module.Features of the module. Compatible SCANport products and programmable
controllers. Parts and hardware of the module. Steps for setting up the
module.Required tools and equipment.Description of the Remote I/O Communications
Modules The Remote I/O communications module is an optional interface designed
to provide a direct, digital link between an AB programmable
controller and any one AB SCANport product. A module is required for
each product that you want to connect to Remote I/O. There are three types of
Remote I/O communications modules
1771-NIVT Analog Input Module AB
1771-NOC Analog Output Module AB
1771-NOV Analog Output Module AB
1771-NOV A High Resolution Isolated Analog Module AB
1771-NR Analog Input Module AB
1771-NT1 Analog Input Module AB
1771-NT2 Analog Input Module AB
1771-OA Digital Output Module AB
1771-OAD AC Output Module AB
1771-OAN Digital Output Module AB
1771-OBD Digital Output Module AB
1771-OBN Digital Output Module AB
1771-OC Digital Output Module AB
1771-OD Digital Output Module AB
1771-OD16 Digital Output Module AB
1771-ODC Digital Output Module AB
1771-ODD Digital Output Module AB
1771-ODZ Digital Output Module AB
1771-OFE1 960578 Analog Output Module AB
1771-OFE2 Analog Output Module AB
1771-OFE3 Analog Output Module AB
1771-OG TTL Output Module AB
1771-OGD TTL Output Module AB
1771-OM Digital Output Module AB
1771-OMD AC Output Module AB
1771-ON Digital Output Module AB
1771-OP Digital Output Module AB
1771-OQ Digital Output Module AB
1771-OQ16 1771-OQ16 A Digital Output Module AB
1771-OR Digital Output Module AB
1771-OVN Digital Output Module AB
1771-OW Selectable Contact Module AB
The use of the product:
1.chemical,
2.transmission and distribution.
3.combustion control systems,
1. Provides the lowest Total Cost of Ownership (TCO)
2. new and original
3.1 year warranty
Our advantages:
1. Customer service in 1-4 hours. If there's any question, please contact with our sales.
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1. Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
2.Q:Does your goods are new and original ?
A: yes ,they are new and original
3.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )