Allen Bradley Modules 1756-ENBT 1756ENBT AB 1756 ENBT A Ethernet/IP Communications Reasonable price
Product Description:
The Remote I/O communications module allows a SCANport product to look and act like a Remote I/O chassis when connected to a programmable controller. Data contained in the input/output image table is transferred between the programmable controller by the Remote I/O scanner, the same as with any Remote I/O chassis. You control the location of data transferred by setting the rack address and
starting group. You control the amount of data by setting the DIP switches on SW3. Important: Thecommunications module does not scale the data that is transferred. Consequently, all scaling of the data must be done in the controller. Refer to the user manual for your SCANport product for details on
device units. Important: The Remote I/O to SCANport conversion is asynchronous. Data sent to the adapter for transfer to the drive must be maintained until the drive has received data.DIP switches on SW3 determine how the data contained in the programmable controller I/O image table is used in the drive. Figure shows an I/O image table.
Related Product Recommendation:
1336F-BRF10-AA-EN | 1440-VLF02-01RA | 2711-CBL-HM05 |
1336F-BRF200-AA-EN | 1440-VSE02-01RA | 2711-CBL-HM10 |
1336F-BRF50-AA-EN | 1441-DYN25-2C | 2711-CBL-PM05 |
1336F-BRF75-AE-DE | 1441-DYN25-CAP | 2711-CBL-PM10 |
1336F-MCB-SP1C | 1441-DYN25-CBL2CH | 2711-NB3 |
1336F-MCB-SP1F | 1441-DYN25-CBLHS | 2711-NB4 |
1336F-MCB-SP1K | 1441-DYN25-CD | 2711-NC13 |
1361-NO61-2-5 | 1441-DYN25-M4CH | 2711-NC14 |
1394-AM75 | 1441-DYN25-MBAL | 2711-NC21 |
1394-SJT05-C-RL? | 1441-DYN25-MBMP | 2711-NC22 |
1394C-AM04 | 1441-DYN25-MFRF | 2711-ND3CNM |
1394C-AM07 | 1441-DYN25-MREC | 2711-ND3DEM |
1395-A65N-C1-PZ | 1441-DYN25-MRUC | 2711-ND3ESM |
140CRP93100 | 1441-DYN25-PS | 2711-ND3FRM |
1440-ACNR | 1441-DYN25-Z-2C | 2711-ND3M |
1440-DYN02-01RJ | 1441-PEN25-BAT | 2711-NF1 |
1440-TB-A | 1441-PEN25-HS | 2711-NF4 |
1440-TBS-J | 1441-PEN25-KIT-BAL | 2711-NF7 |
1440-VSE02-01RA | 1441-PEN25-MOD-2CH | 2711-NL1 |
1492-XIM4024-16R | 1441-PEN25-MOD-BAL | 2711-NL10 |
15-131623-00 | 1441-PEN25-MOD-BMP | 2711-NL5 |
1734-ACNR | 1441-PEN25-MOD-FRF | 2711-NL6 |
1746-BTM | 1441-PEN25-MOD-REC | 2711-NL7 |
1746-C9 | 1441-PEN25-MOD-RUCD | 2711-NL9 |
1746-FIO4V | 1441-PEN25-NS | 2711-NM13 |
1769-IQ16 | 1441-PEN25-PSC-US | 2711-NM15 |
1769-IQ32T | 1441-PEN25-Z2-100 | 2711-NM2 |
1769-IQ6XOW4 | 1442-DR-1150 | 2711-NM232 |
1769-IR6 | 1442-DR-1190 | 2711-NMCC |
1769-L20 | 1442-DR-1850 | 2711-NMCD |
1769-L30 | 1442-DR-1890 | 2711-NMCE |
1769-L31 | 1442-DR-2550 | 2711-NP2 |
1442-DR-2590 | 2711-NR5K |
Product's Character:
The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.). The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix processor. At this point, I/O between the ControlLogix processor and the 1203-CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please contact technical support.
1746-NO4I Analog Current Output Module AB
1746-NO4V Analog Voltage Output Module AB
1746-NO8I Analog Current Output Module AB
1746-NO8V Analog Voltage Output Module AB
1746-NR4 RTD Input Module AB
1746-NR8 RTD Input Module AB
1746-NT4 Thermocouple Input Module AB
1746-NT8 Thermocouple Input Module AB
1746-OA16 120/240V AC Output Module AB
1746-OA8 120/240V AC Output Module AB
1746-OAP12 High Current 120/240V AC Output Module AB
1746-OB16 Current Sourcing DC Output Module AB
1746-OB16E Isolated Sourcing DC Output Module AB
1746-OB32 Current Sourcing DC Output Module AB
1746-OB32E Isolated Sourcing DC Output Module AB
1746-OB6EI Isolated Sourcing DC Output Module AB
1746-OB8 Current Sourcing DC Output Module AB
1746-OBP16 High Current Sourcing DC Output Module AB
1746-OBP8 High Current Sourcing DC Output Module AB
1746-OG16 Current Sinking TTL Output Module AB
1746-OV16 Current Sinking DC Output Module AB
1746-OV32 Current Sinking DC Output Module AB
1746-OV8 Current Sinking DC Output Module AB
1746-OVP16 High Current Sinking DC Output Module AB
1746-OW16 Relay Output Modle AB
1746-OW4 Relay Output Modle AB
1746-OW8 Relay Output Modle AB
1746-OX8 Relay Output Modle AB
1746-P1 Power Supply Module AB
1746-P2 Power Supply Module AB
1746-P3 Power Supply Module -DC AB
1746-P4 Power Supply Module AB
1746-P5 Power Supply Module -DC AB
1746-P6 Power Supply Module -DC AB
1746-P7 Power Supply Module -DC AB
1746-QS Synchronized Axes Module AB
1746-QV Open-Loop Velocity Module AB
1746-SIM Input Simulator AB
1746SC-INI4I Analog Current Input Module Spectrum Controls
1746SC-INO4I Analog Current Output Module Spectrum Controls
The use of the product:
1.paper printing,
2.textile printing and dyeing,
3.machinery,
1. Optimize plant operations
2. new and original
3.1 year warranty
Our advantages:
1. We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1. Q:Does your goods are new and original ?
A: yes ,they are new and original
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )