Send Message
MOORE AUTOMATION LIMITED
Email miya@mvme.cn TEL: 86-180-20776792
Home > products > Allen Bradley Modules >
Allen Bradley Modules 1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT effective service
  • Allen Bradley Modules 1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT effective service

Allen Bradley Modules 1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT effective service

Place of Origin USA
Brand Name Allen Bradley Modules
Certification CO.CQ
Model Number 1756-L1
Product Details
Manufacture Year:
2016
Control System:
Allen Bradley Modules
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT
Weight:
4lbs
High Light: 

allen bradley plc 5

,

controlnet bridge module

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

Allen Bradley Modules 1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT effective service

 

Product Description:

 

Advanced multi-processor design for leading-edge velocity loop bandwidth, fully digital current, velocity, and position loopsLarge-scale integration with custom ASICs and IPMs for performance and reliabilityA 16-bit A/D convertor for precise velocity command input Flash memory for simple field upgrades A personality module to store setup parameters and simplify drive replacement Reduced component count for reliability Internally-shielded filters for electromagnetic compatibility (EMC) Four dedicated I/O plus eight user-selectable, optically isolated digital inputs and outputs (sourcing/active high):Two dedicated inputs Two dedicated outputs Four user-selectable inputs Four user-selectable outputs Two analog inputs for external current limit Two analog outputs for variable monitoring or torque sharing The purpose of this manual is to provide the user with the necessary information to install, program, start up and maintain the Bulletin 1305 drive. To assure successful installation and operation, the material presented must be thoroughly read and understood before proceeding. Particular attention must be directed to the ATTENTION and Important statements contained within.

 

Related Product Recommendation:

 

2094-AM01 1442-EC-1180N 2711-CBL-HM05
2094-AM02-S 1442-EC-1840A 2711-CBL-HM10
2094-BC01-M01-S 1442-EC-1880A 2711-CBL-PM05
2094-BM05 1442-EC-2540A 2711-CBL-PM10
2094-BMP5-S 1442-EC-2580A 2711-NB3
2098-DSD-020X 1442-EC-5040A 2711-NB4
2098-DSD-HV100-SE 1442-EC-5080A 2711-NC13
2706-M1N1 1442-EC-5840A 2711-NC14
2706-P22R 1442-EC-5840N 2711-NC21
2707-L40P2 1442-EC-5845A 2711-NC22
2711-B5A8X 1442-EC-5845N 2711-ND3CNM
2711-B6C1 1442-EC-5880A 2711-ND3DEM
2711-B6C10 1442-EC-5880N 2711-ND3ESM
2711-K10C1 1442-EC-5885A 2711-ND3FRM
2711-K10C15L1 1442-EC-5885N 2711-ND3M
2711-K5A5 1442-PR-0803M0505N 2711-NF1
2711-T10C15 1442-PR-0803M0510N 2711-NF4
2711-T5A10L1 1442-PR-0812E0205N 2711-NF7
2711P-B6C20D 2711P-RN10C 1442-PR-0812E0210N 2711-NL1
2711P-RC3 1442-PS-0503M0010A 2711-NL10
2711P-RN10C/2711P-T6C20D 1442-PS-0503M0010N 2711-NL5
2711P-T12C6D2 1442-PS-0505M0010A 2711-NL6
2711P-T12C6D2 2711P-T12C6B2 1442-PS-0505M0010N 2711-NL7
2711P-T15C4D1 1442-PS-0507M0010A 2711-NL9
1794-TB3S 1442-PS-0507M0010N 2711-NM13
1794-TBN 1442-PS-0509M0010A 2711-NM15
1794-TBNF 1442-PS-0509M0010N 2711-NM2
1794-VHSC 1442-PS-0512E0010A 2711-NM232
193-ECPM3 1442-PS-0512E0010N 2711-NMCC
1769-L20 1442-PS-0512M0010A 2711-NMCD
1769-L30 1442-PS-0512M0010N 2711-NMCE
1769-L31 1442-PS-0515M0010A 2711-NP2
  1442-PS-0515M0010N 2711-NR5K

 

Product's Character:

 

The ground conductor of the motor cable should be connected to the drive ground (GRD) terminal directly. Connecting this ground conductor to a cabinet ground point or ground bus bar may cause high frequency current to circulate in the ground system of the enclosure. The motor end of this ground
conductor must be solidly connected to the motor case ground. Shielded or armored cable may be used to guard against radiated emissions from the motor cable. The shield or armor should be connected to the drive ground terminal and the motor ground as outlined in the Grounding section of this Installation
chapter. Common mode chokes are recommended at the drive output to reduce the common mode noise. An RFI filter can be used and in most situations provides an effective reduction of RFI emissions that may be conducted into the main supplylines. If the installation combines a drive with sensitive devices or circuits,it is recommended that the lowest possible drive PWM frequency be programmed.

Allen Bradley Modules 1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT effective service 0

 

 

1746-NR4 RTD Input Module AB
1746-NR8 RTD Input Module AB
1746-NT4 Thermocouple Input Module AB
1746-NT8 Thermocouple Input Module AB
1746-OA16 120/240V AC Output Module AB
1746-OA8 120/240V AC Output Module AB

1746-OAP12 High Current 120/240V AC Output Module AB
1746-OB16 Current Sourcing DC Output Module AB
1746-OB16E Isolated Sourcing DC Output Module AB
1746-OB32 Current Sourcing DC Output Module AB
1746-OB32E Isolated Sourcing DC Output Module AB
1746-OB6EI Isolated Sourcing DC Output Module AB
1746-OB8 Current Sourcing DC Output Module AB
1746-OBP16 High Current Sourcing DC Output Module AB
1746-OBP8 High Current Sourcing DC Output Module AB
1746-OG16 Current Sinking TTL Output Module AB
1746-OV16 Current Sinking DC Output Module AB
1746-OV32 Current Sinking DC Output Module AB
1746-OV8 Current Sinking DC Output Module AB
1746-OVP16 High Current Sinking DC Output Module AB
1746-OW16 Relay Output Modle AB
1746-OW4 Relay Output Modle AB
1746-OW8 Relay Output Modle AB
1746-OX8 Relay Output Modle AB
1746-P1 Power Supply Module AB
1746-P2 Power Supply Module AB
1746-P3 Power Supply Module -DC AB
1746-P4 Power Supply Module AB
1746-P5 Power Supply Module -DC AB
1746-P6 Power Supply Module -DC AB
1746-P7 Power Supply Module -DC AB
1746-QS Synchronized Axes Module AB
1746-QV Open-Loop Velocity Module AB
1746-SIM Input Simulator AB
1746SC-INI4I Analog Current Input Module Spectrum Controls
1746SC-INO4I Analog Current Output Module Spectrum Controls

 

Allen Bradley Modules 1756-L1 1756L1 AB 1756L1 ControlLogix PROCESSOR UNIT effective service 1

 

The use of the product:

 

1.oil and gas,


2.textile printing and dyeing,

 

3.machinery,

 
Product's advantages:
 

1.Improve efficiency


2. new and original


3.1 year warranty

 

Our advantages:

 

1. 365 days warranty for all the goods from us.


2.2000+ suppliers with us, we could help you to get any components which is difficult to get.


3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.

 
Frequently Asked Questions:
 

1. Q:How about the payment terms ?
A:We frequently use T/T

 

2.Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.

 

3.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
 
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us