  • Allen Bradley Modules 1756-L55M24 1756 L55M24 AB 1756L55M24 CPU Module Highest version

Allen Bradley Modules 1756-L55M24 1756 L55M24 AB 1756L55M24 CPU Module Highest version

Place of Origin USA
Brand Name Allen Bradley Modules
Certification CO.CQ
Model Number 1756-L55M24
Product Details
Manufacture Year:
2016
Control System:
Allen Bradley Modules
Application:
Nuclear Power Plant
Lead Time:
In Stock
Description:
1756-L55M24 1756 L55M24 AB 1756L55M24 CPU Module
Weight:
4lbs
High Light: 

allen bradley cpu

,

controlnet bridge module

Payment & Shipping Terms
Minimum Order Quantity
1
Price
inquiry
Packaging Details
new and original with factory sealed
Delivery Time
today
Payment Terms
T/T
Supply Ability
10 pieces a day
Product Description

Allen Bradley Modules 1756-L55M24 1756 L55M24 AB 1756L55M24 CPU Module Highest version

 

Product Description:

 

The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.). The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix processor. At this point, I/O between the ControlLogix processor and the 1203-CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please contact technical support.

 

Related Product Recommendation:

 

150-SB1NBD 1442-PS-0860E0005N 2711-CBL-HM05
150-SB1NBR 1442-PS-0860E0010A 2711-CBL-HM10
150-SB1NUD 1442-PS-0860E0010N 2711-CBL-PM05
150-SB1NUR 1442-PS-1104M0510A 2711-CBL-PM10
150-SB2NBD 1442-PS-1104M0510N 2711-NB3
150-SB2NBR 1442-PS-1116E0510A 2711-NB4
150-SB2NUD 1442-PS-1116E0510N 2711-NC13
150-SB2NUR 1442-PS-1805M0510A 2711-NC14
150-SB3NBD 1442-PS-1820E0510A 2711-NC21
150-SB3NBR 1442-PS-2505M0510A 2711-NC22
150-SB3NUD 1442-PS-2507N0010A 2711-ND3CNM
150-SB3NUR 1442-PS-2520E0510A 2711-ND3DEM
150-SB4NBD 1442-PS-5005M0010A 2711-ND3ESM
150-SB4NBR 1442-PS-5020E0010A 2711-ND3FRM
150-SB4NUD 1485C-P1A150 2711-ND3M
150-SB4NUR 1485C-P1A300 2711-NF1
150-SC1NBD 1485C-P1A50 2711-NF4
150-SC1NBR 1485C-P1A500 2711-NF7
150-SC1NUD 1485C-P1BS200 2711-NL1
150-SC1NUR 1485C-P1BS420 2711-NL10
150-SC2FBD-1-3B-4R-6P-BP 1485C-P1BS75 2711-NL5
150-SC2NBD 1485C-P1CG150 2711-NL6
150-SC2NBR 1485C-P1CG300 2711-NL7
150-SC2NUD 1485C-P1CG50 2711-NL9
150-SC2NUR 1485C-P1CG600 2711-NM13
1485C-R1CG50 1485C-P1E200 2711-NM15
1485C-R1CG600 1485C-P1E420 2711-NM2
1485C-R1M5-C 1441-DYN25-2C 2711-NM232
193-ECPM3 1442-PS-0816E0005A 2711-NMCC
1769-L20 1442-PS-0816E0005N 2711-NMCD
1769-L30 1442-PS-0816E0010A 2711-NMCE
1769-L31 1442-PS-0515M0010A 2711-NP2
  1442-PS-0515M0010N 2711-NR5K

 

Product's Character:

 

After starting RSLogix 5000 and either starting a new project or opening an existing project, make sure
that you are OFFLINE with the ControlLogix processor. I/O configuration is only available when offline.
If you have not already defined the contents of your ControlLogix chassis under your project's "I/O
Configuration" folder, you will need to define the ControlNet bridge module at a minimum. Use the right
mouse button to click on the "I/O Configuration" folder, then choose "New Module" from the pop-up menu.From the dialog box that appears, choose the ControlNet bridge of the type (1756-CNB or 1756-CNBR)and series that you are using. In the next screen, you will need to name the ControlNet bridge and
indicate its position in the ControlLogix chassis (slot 0 is the leftmost).After defining the ControlNet bridge, use the right mouse button to click on the ControlNet bridge under"I/O configuration", then choose "New Module" from the pop-up menu

 

Allen Bradley Modules 1756-L55M24 1756 L55M24 AB 1756L55M24 CPU Module Highest version 0

 

 

1747-NP1 Wall Mount Power Supply AB
1747-OCKTX Open Controller - Communication Interface Module AB
1747-OCPCI4 Open Controller PCI Backplane AB
1747-OCVGA1 Open Controller - VGA Interface Module AB
1747-PIC PC Interface Converter AB
1747-PSD Program Storage Device AB
1747-PT1 Hand Held Terminal AB
1747-SCNR ControlNet Scanner Module AB
1747-SDN DeviceNet Scanner Module AB
1747-SN Remote I/O Scanner AB
1747-UIC USB to DH-485 Interface Converter AB
1747OC-EDEBA Open Controller - CPU Module AB
1756-A13/A 13 Slot Chassis - Series A AB
1756-A13/B 13 Slot Chassis - Series B AB
1756-A17/A 17 Slot Chassis - Series A AB
1756-A17/B 17 Slot Chassis - Series B AB
1756-BA2 Battery Assembly AB
1756-CNB/D ControlNet Bridge Module - Series D AB
1756-CNB/E ControlNet Bridge Module - Series E AB
1756-DHRIO/B DH+/RIO Bridge/Scanner Module - Series B AB
1756-DHRIO/C DH+/RIO Bridge/Scanner Module - Series C AB
1756-DHRIO/D DH+/RIO Bridge/Scanner Module - Series D AB
1756-DHRIO/E DH+/RIO Bridge/Scanner Module - Series E AB
1756-DNB/A DeviceNet Bridge/Scanner Module - Series A AB
1756-DNB/B DeviceNet Bridge/Scanner Module - Series B AB
1756-DNB/D DeviceNet Bridge/Scanner Module - Series D AB
1756-DNB/E DeviceNet Bridge/Scanner Module - Series E AB
1756-IB16/A Digital Input Module AB
1756-IB16D/A Digital Input Module AB

 

Allen Bradley Modules 1756-L55M24 1756 L55M24 AB 1756L55M24 CPU Module Highest version 1

 

The use of the product:

 

1.energy,


2.tobacco,

 

3.machinery,

 
Product's advantages:
 

1.Experienced technichal support team.


2. new and original


3.1 year warranty

 

Our advantages:

 

1. We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.


2.2000+ suppliers with us, we could help you to get any components which is difficult to get.


3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.

 
Frequently Asked Questions:
 

1.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on

 

2.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !

 

3.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before

 

Send your Inquiry details in the Below, Click "Send" Now!

 
Contact Information:
 
Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
 
 

Contact Us at Any Time

86-180-20776792
32D floor ,GuoMao building , Hubin South Road, Siming District,Xiamen City,Fujian Province,China.
Send your inquiry directly to us