Product Details:
|
|
Place of Origin: | USA |
---|---|
Brand Name: | Allen Bradley Modules |
Certification: | CO.CQ |
Model Number: | 1784-KTCX15 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | inquiry |
Packaging Details: | new and original with factory sealed |
Delivery Time: | today |
Payment Terms: | T/T |
Supply Ability: | 10 pieces a day |
Detail Information |
|||
Manufacture Year: | 2016 | Control System: | Allen Bradley Modules |
---|---|---|---|
Application: | Nuclear Power Plant | Lead Time: | In Stock |
Description: | 1784-KTCX15 1784 KTCX15 AB 1784KTCX15 Communication Card | Weight: | 4lbs |
High Light: | allen bradley plc 5,controlnet bridge module |
Product Description
Allen Bradley Modules 1784-KTCX15 1784 KTCX15 AB 1784KTCX15 Communication Card supply to worldwide
Product Description:
The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.). The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix processor. At this point, I/O between the ControlLogix processor and the 1203-CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please contact technical support.
Related Product Recommendation:
1769-ECR | 1746-HSCE2 | 1785-L40C15 |
1769-IA16 | 1746-HSRV | 1785-L40E |
1769-IF4FXOF2F | 1746-HT | 1785-L60B |
1769-IQ16 | 1746-IA8 | 1785-L60L |
1769-IQ32T | 1746-IC16 | 1785-L80B |
1769-IQ6XOW4 | 1746-IH16 | 1785-L80C |
1769-IR6 | 1746-IO12 | 1785-L80C15 |
1769-L20 | 1746-IO8 | 1785-LT3 |
1769-L30 | 1746-ITB16 | 1785-LTB |
1769-L31 | 1746-ITV16 | 1785-ME16 |
1769-L32E | 1746-IV16 | 1785-ME32 |
1769-L35E | 1746-IV32 | 1785-PFB |
1769-OA8 | 1746-N2 | 1785-V40L |
1769-OB32 | 1746-NI04I | 1785-V40V |
1769-OF8V | 1746-NIO4V | 1785-V80B |
1769-OV16 | 1746-NO4I | 1786-BNC |
1769-OV32T | 1746-NO4V | 1786-RPA |
1769-OW8 | 1746-NR4 | 1786-RPFM |
1769-SM1 | 1746-NT4 | 1786-RPFRL |
1769-SM2 | 1746-OA16 | 1786-RPFRXL |
1770-KF2 | 1746-OAP12 | 1788-CN2FF |
1770-KFD | 1746-OB16E | 1788-CNC |
1770-XYC | 1746-OB8 | 1788-CNET |
1768-L43 | 1441-DYN25-2C | 1788-ENBT |
1768-L43S | 1441-DYN25-CAP | 1790D-TN4V0 |
1768-L45 | 1441-DYN25-CBL2CH | 1791-16A0 |
1768-M04SE | 1441-DYN25-CBLHS | 1791-16AC |
1769-ADN | 1441-DYN25-CD | 1791-16BC |
1769-ASCII | 1441-DYN25-M4CH | 1793-OB16P |
1756-LSP | 1441-DYN25-MBAL | 1794-ACNR15 |
1756-M02AE | 1441-DYN25-MBMP | 1794-CE1 |
Product's Character:
Appendix B provides information about the Block Transfer messages supported by the Remote I/O communications module. In this appendix, you will read about the following: Block transfer status word.
Setting up data files for block transfer messages.Examples of block transfer messages. Block transfer quick reference. Important: This appendix provides detailed examples of block transfer messages. For information about block transfer messages, also refer to Chapter 5.Chapter 1 provides an overview of the
Remote I/O communications module (1203-GD1 module, 1203-GK1 module, and 1336-GM1 board). In this chapter, you will read about the following:Function of the module.Features of the module. Compatible SCANport products and programmable controllers. Parts and hardware of the module. Steps for setting up the module.Required tools and equipment.Description of the Remote I/O Communications Modules The Remote I/O communications module is an optional interface designed to provide a direct, digital link between an AB programmable controller and any one AB SCANport product. A module is required for each product that you want to connect to Remote I/O. There are three types of Remote I/O communications modules
1771-P4 Power Supply Module AB
1771-P4R Power Supply AB
1771-P4S Power Supply Module AB
1771-P4S1 Power Supply AB
1771-P5 Power Supply AB
1771-P5E Power Supply AB
1771-P6R Power Supply AB
1771-P6S Power Supply AB
1771-P6S1 Power Supply AB
1771-P7 Power Supply AB
1771-PA Power Supply Module AB
1771-PS7 Power Supply Module AB
1771-PS7C Power Supply Assy. 120/220 AC AB
1771-QB Linear Positioning Module AB
1771-RTP4 TYP UMK-SE 11,25-1 902-RTP Remote Termination Panel AB 1
1771-SDN/B 1771-SDN Devicenet Scaner Module AB
1771-SIM Simulator Module AB
1771-SN Sub I/O Scanner Module AB
1771-VHSC Very High Speed Counter Module AB
1771-WA Field Wiring Arm AB
1771-WB Field Wiring Arm,12 Terminals AB
1771-WC Field Wiring Arm AB
1771-WD Field Wiring Arm,12 Terminals AB
1771-WH Field Wiring Arm, 16 I/O channels (21 terminals) AB
1771-WN Field Wiring Arm 32 Terminals AB
1772-CS Processor/Scanner Interconnect Cable AB
1772-LH Processor Interface Module AB
1772-LN2 CPU Module AB
1772-LP2 PLC-2/20 PLC-2/20 Processor Unit AB
1772-LP3 PLC-2/30 PLC-2/30 Processor Unit AB
1772-LS PLC-2/05 PLC-2/05 Processor AB
1772-LW PLC 2/17 MINI PLC 2/17 Processor AB
1772-LWP D PLC2 DNGL SL 6K Proc AB
1772-LX/C PLC 2/16 Mini PLC 2/16 Processor AB
1772-LX/D PLC 2/16 Mini PLC 2/16 Processor AB
All parameters required for any given drive function will be contained within a group, eliminating the need to changegroups to complete a function.To help differentiate parameter names and display text from
other text in this manual, the following conventions will be used – Parameter Names will appear in [Brackets] – Display Text will appear in “Quotes.” Parameter information in this chapter is presented for users who have a Human Interface Module (HIM) installed. For those users without a HIM installed, the
drive can be operated using the factory default values for each parameter or parameter values can be changed through the serial port. FUNCTION INDEX The Function Index shown provides a directory of various drive functions. The Page Number will direct you to the parameters associated with each function.
The use of the product:
1.energy,
2.municipal engineering,,
3 water, water treatment / environmental protection,
1.Customer service in 1-4 hours. If there's any question, please contact with our sales.
2.Provides the lowest Total Cost of Ownership (TCO)
3.emission reduction
Our advantages:
1.We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.
1.Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.
2.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Enter Your Message