Product Details:
|
|
Place of Origin: | Sweden |
---|---|
Brand Name: | Allen Bradley Modules |
Certification: | CO.CQ |
Model Number: | 1794-IB8 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | inquiry |
Packaging Details: | new and original with factory sealed |
Delivery Time: | today |
Payment Terms: | T/T |
Supply Ability: | 10 pieces a day |
Detail Information |
|||
Manufacture Year: | 2016 | Control System: | Allen Bradley Modules |
---|---|---|---|
Application: | Nuclear Power Plant | Lead Time: | In Stock |
Description: | 1794-IB8 1794IB8 AB 1794 IB8 FLEX I/O Input Module | Weight: | 4lbs |
High Light: | allen bradley plc 5,controlnet bridge module |
Product Description
Allen Bradley Modules 1794-IB8 1794IB8 AB 1794 IB8 FLEX I/O Input Module
Product Description:
The Remote I/O communications module allows a SCANport product to look and act like a Remote I/O chassis when connected to a programmable controller. Data contained in the input/output image table is transferred between the programmable controller by the Remote I/O scanner, the same as with any Remote I/O chassis. You control the location of data transferred by setting the rack address and
starting group. You control the amount of data by setting the DIP switches on SW3. Important: Thecommunications module does not scale the data that is transferred. Consequently, all scaling of the data must be done in the controller. Refer to the user manual for your SCANport product for details on
device units. Important: The Remote I/O to SCANport conversion is asynchronous. Data sent to the adapter for transfer to the drive must be maintained until the drive has received data.DIP switches on SW3 determine how the data contained in the programmable controller I/O image table is used in the drive. Figure shows an I/O image table.
Related Product Recommendation:
1442-PR-0803M0510N | 1442-EC-1840A | 1746-HS |
1442-PR-0812E0205N | 1442-EC-1880A | 1746-HSCE2 |
1442-PR-0812E0210N | 1442-EC-2540A | 1746-HSRV |
1442-PS-0503M0010A | 1442-EC-2580A | 1746-HT |
1442-PS-0503M0010N | 1442-EC-5040A | 1746-IA8 |
1442-PS-0505M0010A | 1442-EC-5080A | 1746-IC16 |
1442-PS-0505M0010N | 1442-EC-5840A | 1746-IH16 |
1442-PS-0507M0010A | 1442-EC-5840N | 1746-IO12 |
1442-PS-0507M0010N | 1442-EC-5845A | 1746-IO8 |
1442-PS-0509M0010A | 1442-EC-5845N | 1746-ITB16 |
1442-PS-0509M0010N | 1442-EC-5880A | 1746-ITV16 |
1442-PS-0512E0010A | 1442-EC-5880N | 1746-IV16 |
1442-PS-0512E0010N | 1442-EC-5885A | 1746-IV32 |
1442-PS-0512M0010A | 1442-EC-5885N | 1746-N2 |
1442-PS-0512M0010N | 1442-PR-0803M0505N | 1746-NI04I |
1442-PS-0515M0010A | 1442-PR-0803M0510N | 1746-NIO4V |
1442-PS-0515M0010N | 1442-PR-0812E0205N | 1746-NO4I |
1442-PS-0516E0010A | 1442-PR-0812E0210N | 1746-NO4V |
1442-PS-0516E0010N | 1442-PS-0503M0010A | 1746-NR4 |
1442-PS-0520E0010A | 1442-PS-0503M0010N | 1746-NT4 |
1442-PS-0520E0010N | 1442-PS-0505M0010A | 1746-OA16 |
1442-PS-0530E0010A | 1442-PS-0505M0010N | 1746-OAP12 |
1442-PS-0530E0010N | 1442-PS-0507M0010A | 1746-OB16E |
1442-PS-0540E0010A | 1442-PS-0507M0010N | 1746-OB8 |
1442-PS-0540E0010N | 1442-PS-0509M0010A | 1746-OBP16 |
1442-PS-0550E0010A | 1442-PS-0509M0010N | 1746-OG16 |
1442-PS-0550E0010N | 1442-PS-0512E0010A | 1746-OV32 |
1442-PS-0560E0010A | 1442-PS-0512E0010N | 1746-OV8 |
1442-PS-0560E0010N | 1442-PS-0512M0010A | 1746-OW4 |
1442-PS-0803M0005A | 1442-PS-0512M0010N | 1746-OX8 |
1442-PS-0803M0005N | 1442-PS-0515M0010A | 1746-P1 |
Product's Character:
After starting RSLogix 5000 and either starting a new project or opening an existing project, make sure
that you are OFFLINE with the ControlLogix processor. I/O configuration is only available when offline.
If you have not already defined the contents of your ControlLogix chassis under your project's "I/O
Configuration" folder, you will need to define the ControlNet bridge module at a minimum. Use the right
mouse button to click on the "I/O Configuration" folder, then choose "New Module" from the pop-up menu.From the dialog box that appears, choose the ControlNet bridge of the type (1756-CNB or 1756-CNBR)and series that you are using. In the next screen, you will need to name the ControlNet bridge and
indicate its position in the ControlLogix chassis (slot 0 is the leftmost).After defining the ControlNet bridge, use the right mouse button to click on the ControlNet bridge under"I/O configuration", then choose "New Module" from the pop-up menu
Series A Allen-Bradley
1756-L55M14/A 1756-L55/A, 1756-M14/A Logix5555 Processor, 3.5 MB memory, Series A Allen-Bradley
1756-L55M16/A 1756-L55/A, 1756-M14/A Logix5555 Processor, 7.5 MB memory, Series A Allen-Bradley
1756-L61/A Logix5561 Logix5561 Processor - 2MB Allen-Bradley
1756-L61/B Logix5561 Logix5561 Processor - 2MB Allen-Bradley
1756-L62/A Logix5562 Logix5562 Processor - 4MB Memory Allen-Bradley
1756-L62/B Logix5562 Logix5562 Processor - 4MB Memory Allen-Bradley
1756-OB16E/A Digital Fused Output Module - Series A Allen-Bradley
1756-PA72/A 1756-PA72 Power Supply - Series A Allen-Bradley
1756-PA72/B 1756-PA72 Power Supply - Series B Allen-Bradley
1756-PA72/C 1756-PA72 Power Supply - Series A Allen-Bradley
1761-CBL-PM02 Program Storage Device Cable Allen-Bradley
1761-L32BBB MicroLogix 1000 Unit Allen-Bradley
1762-IQ16 16PT 24VDC Power Supply Module Allen-Bradley
1762-MM1 MicroLogix Memory Module Allen-Bradley
1762-MM1RTC MicroLogix Memory and Real-Time Clock Module Allen-Bradley
1762-OF4 Analog Output Module Allen-Bradley
1762-OW16 16PT VAC/VDC Relay Output Allen-Bradley
1762-RTC MicroLogix Real-Time Clock Module Allen-Bradley
1764-24BWA MicroLogix 1500 Base Unit Allen-Bradley
1764-LRP Processor Allen-Bradley
1764-LSP Processor Module Allen-Bradley
1766-L32BWA Micro Logic Relay Output AC Power Allen-Bradley
1769-ECR Right End Cap Allen-Bradley
1769-IF4 Analog Input Module Allen-Bradley
1769-IQ16 Digital Input Module Allen-Bradley
AMP Fibre Fiber Channel Cables 038-003-022 *TWO*
EMC P/N 038-003-509 REV A03 2M *TWO*
EMC AA23540 EMC P/N 078-000-033 STANDBY POWER SUPPLY
EMACS M1K-2A00V 100-240V 47-63Hz 15-7.5A 1000W
TELLABS 011-0009 REV 5C SBTCHGSBAC
Cisco HWIC-4A/S 4-Port Async/Sync Serial 73-9117-05 A1
TAMAGAWA TS1982N53E6 DC SERVE MOTOR ENCODER
POWER-ONE SP615 BABT
INTEL 38921924 PRO 100S DESKTOP ADAPTER WITH ETHEREXPRESS FOR WINDOWS 9X
DELL 7000679-0000 730WATTS 12A
HP P/N 361392-001 MODEL DPS -460BB B
Cyclades Ze Host Card 9-PCBS-0033 V1.02
HARAX M8-S 4 POL. STIFT ART. NR. 21021511405 00
DPH-103 Panasonic / Sunx Pressure Sensor 1V to 5V 0kPa to 101kPa Vacuum Gage
HARTING 21011404071 CIRCULAR CONNECTOR WITH HARAX RAPID TERMINATION TECHNIQUE
A10 NETWORKS AX2000 ADVANCED TRAFFIC MANAGER LOAD BALANCER
DELL POWEREDGE 8 Port CONSOLE SWITCH
EMACS POWER SUPPLY MODEL MPB-6180F
DWYER INSTRUMENTS PRESSURE SWITCH CAT 19 WITH CORD
ATI MACH32 VGA VIDEO ADAPTER P/N 109-22900-30
The use of the product:
1.provides integrated control, power, safety,
2.Avoid unplanned downtime
3.Provides the lowest Total Cost of Ownership (TCO)
1.Optimize plant operations
2.emission reduction
3.Avoid unplanned downtime
1.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before
2.Q:How about the payment terms ?
A:We frequently use T/T
3.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Enter Your Message