Allen Bradley 1485C-P1A500 1485C P1A500 AB 1485CP1A500
Product Description:
For the requested packet interval, enter the number of milliseconds desired between each I/O message
between the ControlLogix processor and the 1203-CN1. The 1203-CN1 can handle a packet interval as
low as 5 milliseconds; therefore, make sure that this value is set to at least Click the "Finish" button to
complete the configuration of the I/O connection in RSLogix 5000. At this point, download your configuration to the ControlLogix processor, then exit RSLogix 5000. To actually schedule the I/O, you will need to start RSNetWorx for ControlNet. Once RSNetWorx starts, go online to the ControlNet network
containing the ControlLogix chassis and 1203-CN1 being configured. Turn on the "Enable Edits" check box, then save the network. This causes the I/O connection created in RSLogix 5000 to be scheduled in the ControlLogix processor. After a few seconds, the I/O LED on the ControlLogix processor and the
module LED on the 1203-CN1 should stop blinking and remain green. If they do not, it could indicate a number of I/O-related problems
Contact Information:
Contact:Miya ( manager)
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
Related Product Recommendation:
1769-OB32 | 1747-L20C | 1746-IH16 |
1769-OF8V | 1747-L30C | 1746-IO12 |
1769-OV16 | 1747-L514 | 1746-IO8 |
1769-OV32T | 1747-L524 | 1746-ITB16 |
1769-OW8 | 1747-L531 | 1746-ITV16 |
1769-SM1 | 1747-L541 | 1746-IV16 |
1769-SM2 | 1747-L542 | 1746-IV32 |
1770-KF2 | 1747-L543P | 1746-N2 |
1770-KFD | 1747-L551 | 1746-NI04I |
1770-XYC | 1747-L553 | 1746-NIO4V |
1771-A2B | 1747-M11 | 1746-NO4I |
1771-CP1 | 1747-MNET | 1746-NO4V |
1771-DB | 1747-OCPCM2 | 1746-NR4 |
1771-DXPS | 1747-OCVGA1 | 1746-NT4 |
1771-HS3A | 1747-SCNR | 1746-OA16 |
1771-IAD | 1747-SDN | 1746-OAP12 |
1771-IAN | 1747OC-EBCBA | 1746-OB16E |
1771-IB | 1756-A17 | 1746-OB8 |
1771-IFEK | 1756-BA1 | 1746-OBP16 |
1771-IFM | 1756-BA2 | 1746-OG16 |
1771-IK | 1756-CFM | 1746-OV32 |
1771-IL | 1756-CN2 | 1746-OV8 |
1771-IR | 1756-CN2R | 1746-OW4 |
1771-NC15 | 1756-CNB | 1746-OX8 |
1771-NC6 | 1756-CNB | 1746-P1 |
1762-L40BWA | 1756-CNBR | 1746-P2 |
1764-24BWA | 1440-ACNR | 1746SC-IA8I |
The Remote I/O communications module allows a SCANport product to look and act like a Remote I/O chassis when connected to a programmable controller. Data contained in the input/output image table is transferred between the programmable controller by the Remote I/O scanner, the same as with any
Remote I/O chassis. You control the location of data transferred by setting the rack address and
starting group. You control the amount of data by setting the DIP switches on SW3. Important: Thecommunications module does not scale the data that is transferred. Consequently, all scaling of the
data must be done in the controller. Refer to the user manual for your SCANport product for details on
device units. Important: The Remote I/O to SCANport conversion is asynchronous. Data sent to the adapter for transfer to the drive must be maintained until the drive has received data.DIP switches on
SW3 determine how the data contained in the programmable controller I/O image table is used in the drive. Figure shows an I/O image table.
1747-ACN15 ControlNet Adapter Module AB
1747-ACNR15 ControlNet Adapter Module AB
1747-AIC Isolated Link Coupler AB
1747-ASB Remote I/O Adapter AB
1747-BSN Backup Remote I/O Scanner AB
1747-C11-A Programmer Cable AB
1747-DCM 1747-DCM A Direct Communication Module AB
1747-DPS2 Configurable Port Splitter AB
1747-FC Ferrite Collar AB
1747-KE Interface Module AB
1747-KFC15 ControlNet Messaging Module AB
1747-L20A/A 1747-L20A Processor Unit - Series A AB
1747-L20A/B 1747-L20A Processor Unit - Series B AB
1747-L20A/C 1747-L20A Processor Unit - Series C AB
1747-L20B/B 1747-L20B Processor Unit - Series B AB
1747-L20C/B 1747-L20C Processor Unit - Series B AB
1747-L20C/C 1747-L20C Processor Unit - Series C AB
1747-L30A/B 1747-L30A Processor Unit - Series B AB
1747-L30B/B 1747-L30B Processor Unit - Series B AB
1747-L30C/B 1747-L30C Processor Unit - Series B AB
1747-L40A/B 1747-L40A Processor Unit - Series B AB
1747-L40A/C 1747-L40A Processor Unit - Series C AB
1747-L40B/B 1747-L40B Processor Unit - Series B AB
1747-L40L 1747-L40L Processor Unit - Series A AB
1747-L511 SLC 5/01 SLC 5/01 Controller AB
1747-L511/A SLC 5/01 SLC 5/01 Controller AB
1747-L511/B SLC 5/01 SLC 5/01 Controller AB
1747-L514/A SLC 5/01 SLC 5/01 Controller AB
1747-L514/B SLC 5/01 SLC 5/01 Controller AB
1747-L524/C SLC 5/02 SLC 5/02 Controller AB
1747-L531/D SLC 5/03 SLC 5/03 Control Processor AB
1747-L531/E SLC 5/03 SLC 5/03 Control Processor AB
1747-L532/A SLC 5/03 SLC 5/03 Control Processor AB
1747-L532/B SLC 5/03 SLC 5/03 Control Processor AB
ADVANTECH PCI-1710 REV.C1-01-1 PCI MULTI-FUNCTION CARD
TROPOS NETWORKS 5210 MOTHERBOARD P/N 300049-01 REV.B2
IDEC Analog Programmable Logic Controller TYPE: FC4A-J8C1
VINTAGE Digital 3.0GB 5.25 FH Single SCSI HD - DSP5300S
CYCLADES ALTERPATH P/N 107-A KVM TERMINATOR KVM ADAPTER DB15M-RJ45-8 ,KB,Mouse
KAPAREL 8SLOT COMPACTPCI BACKPLANE MODEL PS4734-5
ARIEL MM-96 SBC (SINGUE BOARD COMPUTER)
DELL (POWEREDGE) SAS SATA HARD DISK TRAY P/N#CN-0F9541
ZNYX ZX346Q Quad Port 10/100 PCI Ethernet Adapter
Allied Telesyn Centrecom AT-3024SL
FAULHABER MINIMOTOR 2444 S 024 B K903 158762
TELECT P/N 005-0005-0002 X-AISLE 56 CKT 19X 1.75 BLK
EMACS MRG-6500P-R 500 WATT POWER SUPPLY
VIA EPIA MII 1000 - motherboard - mini ITX - VIA C3 - CLE266 - 1.0 GHz (pulled)
CPU PROCESSOR INTEL PENTIUM A80502120 SY033/SSS IPP
APEX PRECISION POWER - PA92 - IC, OP-AMP, 18MHZ, 50V/μs, SIP-12
Advantech PCI-6881 REV. A2
AMD-K5 PR133ABR CPU
HP PA-RISC CPU MODULE - p/n #: A2375-80025
Actiontec External Wireless USB Adapter (802.11b)
HAMILTON GASTIGHT SYRINGE FOR PRECISION MEASURING
Asus TUV4X - 533MHz FSB Socket 370 CPU
BARNSTEAD THERMOLYNE MODEL HPA1915B USED
CHELSIO 110-1064-21 A0
The use of the product:
1.automobile manufacturing,
2.construction machinery,
3. petrochemical,
1.Provides the lowest Total Cost of Ownership (TCO)
2. auto ancillary.
3.1 year warranty
Our advantages:
1.provides integrated control, power, safety,
and information solutions for complete plant-wide control in a scalable,
2.Optimize plant operations
3.emission reduction
Frequently Asked Questions:
1.Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.
2.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
3.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods before1
Send your Inquiry details in the Below, Click "Send" Now!