Allen Bradley Modules 1769-OW8 1769 OW8 AB 1769OW8 I/O Relay Output Module New Sealed
Product Description:
The name of the tag will reflect the name you assigned the earlier. The "C" sub-group contains the contents of the configuration assembly, which is not currently used in the 1203-CN1. The "O" subgroup contains one entry for each word of output data you configured, and the "I" sub-group contains one entry for each word of input data you configured. The "O" sub-group corresponds directly to output data for a PLC-5 described on page 5-2 of the 1203-CN1 user manual (i.e., for most common configurations, word 0 is the logic command, word 1 is the speed reference, words 2 and 3 are the first pair of data links, etc.). The "I" sub-group is similar to the input data for a PLC-5, except that it is shifted by two words (i.e., word 2 is the logic status, word 3 is the speed feedback, etc.). Words 0 and 1 of the "I" sub-group represent network status data sent by the 1203-CN1 but not processed directly by the ControlLogix processor. At this point, I/O between the ControlLogix processor and the 1203-CN1 should be configured and running, and the meaning of the various I/O words should be understood. If you need further assistance in configuring I/O, please contact technical support.
Related Product Recommendation:
|
Product's Character:
For the requested packet interval, enter the number of milliseconds desired between each I/O message
between the ControlLogix processor and the 1203-CN1. The 1203-CN1 can handle a packet interval as
low as 5 milliseconds; therefore, make sure that this value is set to at least Click the "Finish" button to
complete the configuration of the I/O connection in RSLogix 5000. At this point, download your configuration to the ControlLogix processor, then exit RSLogix 5000. To actually schedule the I/O, you will need to start RSNetWorx for ControlNet. Once RSNetWorx starts, go online to the ControlNet network
containing the ControlLogix chassis and 1203-CN1 being configured. Turn on the "Enable Edits" check box, then save the network. This causes the I/O connection created in RSLogix 5000 to be scheduled in the ControlLogix processor. After a few seconds, the I/O LED on the ControlLogix processor and the module LED on the 1203-CN1 should stop blinking and remain green. If they do not, it could indicate a number of I/O-related problems
1747-L532/C SLC 5/03 SLC 5/03 Control Processor AB
1747-L532/D SLC 5/03 SLC 5/03 Control Processor AB
1747-L532/E SLC 5/03 SLC 5/03 Control Processor AB
1747-L541/B SLC 5/04 SLC 5/04 Processor - Series B AB
1747-L541/C SLC 5/04 SLC 5/04 Processor - Series C AB
1747-L542/A SLC 5/04 1747-L542 Processor - Series A AB
1747-L542/B SLC 5/04 1747-L542 Processor - Series B AB
1747-L542/C SLC 5/04 1747-L542 Processor - Series C AB
1747-L543/B SLC 5/04 Processor - Series B AB
1747-L543/C SLC 5/04 Processor - Series C AB
1747-L551/A SLC 5/05 SLC 5/05 Controller AB
1747-L551/B SLC 5/05 SLC 5/05 Controller AB
1747-L551/C SLC 5/05 SLC 5/05 Controller AB
1747-L552/A SLC 5/05 1747-L552 Processor - Series A AB
1747-L552/B SLC 5/05 1747-L552 Processor - Series B AB
1747-L552/C SLC 5/05 1747-L552 Processor - Series C AB
1747-L553/A SLC 5/05 Controller AB
1747-L553/B SLC 5/05 Controller AB
1747-L553/C SLC 5/05 Controller AB
1747-M1 1 K EEPROM Memory Module AB
1747-M11 Flash Memory Module - 32K AB
1747-M12 Flash Memory Module - 64K AB
1747-M13 64 K Flash EPROM Memory Module AB
1747-M15 Adapter Socket AB
1747-M2 4 K EEPROM Memory Module AB
1747-M5 Adapter Socket AB
1747-NP1 Wall Mount Power Supply AB
1747-OCKTX Open Controller - Communication Interface Module
The use of the product:
1.textile printing and dyeing,
2.electricity,
3 water, water treatment / environmental protection,
1.open architecture to take advantage of traditional or renewable sources of energy!
2.Optimize plant operations
3.emission reduction
Our advantages:
1. Avoid unplanned downtime
2.2000+ suppliers with us, we could help you to get any components which is difficult to get.
3.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.
1.Q:Does your goods are new and original ?
A: yes ,they are new and original
2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )