Product Details:
Place of Origin: Germany
Brand Name: Siemens
Certification: CO.CQ
Model Number: 6GK7542-1AX10-0XE0
Detail Information
Place of Origin:
Germany
Brand Name:
Siemens
Certification:
CO.CQ
Model Number:
6GK7542-1AX10-0XE0
Interface Hardware:
2 X RJ45 Ports (integrated 2-port Real-time Switch)
Data Transfer Rate:
10/100 Mbit/s (Fast Ethernet)
PROFINET Roles:
Configurable As A PROFINET IO Controller Or IO Device
Power Ingestion:
3.3 Watts Max Consumption Via The 15 Vdc S7-1500 Backplane Bus
Highlight:

High Light

Highlight:

Dedicated Net Coprocessor: Offloads network communications to free up PLC CPU memory [6GK7542-1AX10-0XE0].

,

Dual-Role PROFINET Engine: Configurable as an IO Controller or IO Device [6GK7542-1AX10-0XE0].

,

TIA Portal V18 Integrated: Simple block-based hardware mapping [6GK7542-1AX10-0XE0].

Trading Information
Minimum Order Quantity:
1
Price:
inquiries
Packaging Details:
new and original with factory sealed
Delivery Time:
2-3 work days
Payment Terms:
T/T
Supply Ability:
requires
Product Description
6GK7542-1AX10-0XE0 Siemens Communication Module
For Connecting SIMATIC S7-1500 To PROFINET As IO Controller Or IO Device
Featuring an independent onboard processor, the 6GK7542-1AX10-0XE0 communication module offloads complex industrial networking tasks from the main CPU while providing a dual-port PROFINET interface. It eliminates the critical technical bottleneck of CPU processing drag and limited connection limits during large-scale network data exchange, seamlessly handling simultaneous I/O controls and IT communications. This makes it the definitive networking solution for connecting SIMATIC S7-1500 PLCs to factory-wide PROFINET architectures as either an IO Controller or IO Device across high-throughput automotive assembly lines and process automation skids.
Engineer's Note
"When configuring the 6GK7542-1AX10-0XE0 in your TIA Portal project, note that this module completely replaces the older `-1AX00-` version and mandates the use of STEP 7 Professional V18 or higher. If you are scaling up an environment with multiple I/O device drops, take advantage of its integrated 2-port switch to build a line or ring network topology without paying extra for external network switches. However, ensure your transmission speed is locked to '100 Mbps full duplex' within your PROFINET properties block to maintain operational deterministic timing."
Real-World Application Case Study
  • Project: Production Line Ethernet Infrastructure Expansion
  • Location: Indonesia (2025 Deployment)
  • Application: This exact communication module model was successfully deployed for a manufacturing plant in Indonesia in 2025, operating flawlessly under tropical humid conditions. Serving as an autonomous processor block, the modules handle heavy industrial multicast messaging and master computer telemetry on critical assembly skids, keeping data pathways open without loading down the host S7-1500 CPU.
Custom Product FAQ
Q: How does this "-1AX10-" model differ from the legacy "-1AX00-" version?
A: The 6GK7542-1AX10-0XE0 is a direct firmware and hardware evolution running the V4.0+ baseline. It incorporates tighter security management layers, improved diagnostics via TIA Portal V18, and completely succeeds the legacy module for all new plant designs.
Q: Can this module run alongside the built-in Ethernet ports on an S7-1500 CPU?
A: Yes. Adding a CM 1542-1 expands your total system bandwidth by providing a completely isolated IP network subnet. This is frequently utilized to separate deterministic field-level I/O traffic on one subnet from local SCADA/ERP supervisory traffic on another.
Q: What is the purpose of the NTP time synchronization feature on this module?
A: The Network Time Protocol (NTP) client allows the module to sync its internal clock with an external plant-wide master clock over Ethernet. It passes this clock stamp down to the PLC backplane, ensuring that diagnostic event logs across distributed automation cells match perfectly.
Recommended Models
6ES5434-4UA11 6ES7288-3AR04-0AA0 6GK1561-4AA02
6ES5441-4UA14 6ES7412-2XG00-0AB0 16267-1/4
6ES5454-4UA13 6DS1916-8RR 6ES7135-0HF01-0XB0
6ES5465-4UA12 6SN1118-0DK23-0AA2 383VA21N1F
6ES5470-4UC12 6GK1901-1BB10-2AE0 39ACM14CAN
6AV6647-0AK11-3AX0 6DD1660-0BJ0 39PSMNAN
6AV6648-0CE11-3AX0 6DD1661-0AE0 39PSR4ANDN 16114-200/01
6DD1681-0CA2 6DD1640-0AD0 39RTMCAN
6DD1601-0AE0 6FC5370-4AM20-0AA0 39VIMCBN
6DD1688-0AD0 6FC5370-8AA20-0AA0 39VIMCCN
Global Business Coverage
  • North America (USA, Canada)
  • Europe (Germany, UK, France, Italy, Spain, etc.)
  • Asia (China, Japan, South Korea, Southeast Asia, India)
  • Middle East (UAE, Saudi Arabia, etc.)
  • South America & others (Brazil, Mexico, Australia)
The Amikon Benefit: 100% Original | Factory Sealed | Lowest Lead Times
Get a Quote Now
Contact: Miya Zheng
WhatsApp: +86 180 2077 6792