The Siemens SIMATIC MP 177 (6AV6642-0EA01-3AX0) bridges the gap between basic operator panels and costly industrial PCs by embedding a Windows CE-based open architecture into a compact, IP65-rated 5.7-inch touchscreen. It solves the critical client pain point of multi-protocol lock-in by integrating onboard PROFINET, PROFIBUS, and MPI interfaces simultaneously, eliminating the need for expensive external communication gateways. Compared to standard HMIs, this multi-panel seamlessly handles complex scripting, data logging, and multi-vendor connectivity, making it the ideal retrofitting or replacement choice for space-constrained motion control systems and complex factory automation cells.
Technical Specifications
| Feature | Specification |
|---|
| Model Number | 6AV6642-0EA01-3AX0 |
| Product Series | SIMATIC MP 177 Touch |
| Display Size & Type | 5.7-inch TFT LCD Display |
| Colors / Resolution | 4 Analog Colors / 320 x 240 Pixels |
| Interfaces | 1 x RJ45 Ethernet (PROFINET), 1 x RS485/RS422 (MPI/PROFIBUS DP), 1 x USB |
| Operating System | Windows CE |
| Configuration Software | WinCC flexible Compact (or higher) / TIA Portal |
| Protection Class | IP65 (Front face when installed) |
Key Features & Benefits
Interfaces: Onboard PROFINET + PROFIBUS DP / MPI
Acts as a universal communication bridge. It lets you connect old and new factory machines simultaneously without buying expensive external protocol converters, saving thousands of dollars in hardware costs during a plant upgrade.
Protection Class: IP65 Rated Front Bezel
Fully oil-mist, dust, and splash-waterproof. This ensures the screen will not short-circuit or freeze when exposed to high-pressure cleaning spray or metallic dust, eliminating premature breakdown costs on a busy factory floor.
Operating System: Windows CE Platform with VB Scripting
Local intelligence. The panel can run complex data-logging and manage massive recipe files directly on its own hardware, meaning you don't need to pay for an expensive, high-tier PLC to handle basic calculation tasks.
Automation Engineer's Note
"When retrofitting legacy lines, our engineering team highly recommends stocking the 6AV6642-0EA01-3AX0 specifically if your system utilizes older PROFIBUS networks alongside modern Ethernet-based PLCs. Because it natively bridges MPI, PROFIBUS, and PROFINET, it allows for a step-by-step plant modernization without forcing you to completely rewrite your PLC code overnight. Note: If you are migrating a project file from WinCC flexible into TIA Portal, ensure you convert the device target to MP 177 before upgrading the project file format to avoid tag mapping compilation errors."
Frequently Asked Questions
Q: This model is flagged as a phase-out product by Siemens. Can it still be directly integrated into a new TIA Portal project?
A: Yes, while it is a legacy multi-panel, the 6AV6642-0EA01-3AX0 remains fully supported as a hardware object up to TIA Portal V14 SP1. For newer TIA Portal versions (V15 through V20+), you must maintain the original project in WinCC flexible 2008, or execute a stepped migration path to transition the HMI tags and screens over to a current Comfort Panel or Unified Comfort Panel equivalent.
Q: What is the most common failure point for the MP 177 in harsh factory environments, and how do we protect it?
A: While the front bezel carries a rugged IP65 dust and waterproof rating, field data shows the resistive touchscreen layer can degrade over time when exposed to heavy chemical solvents or operators using sharp metallic objects. We strongly recommend applying a sacrificial, chemically-resistant protective membrane over the 5.7-inch screen area to double the mechanical service life of the touch matrix in machining or chemical processing cells.
Q: Can the 6AV6642-0EA01-3AX0 store historical alarms and recipes locally if the PLC connection drops?
A: Yes, this is exactly why it is classified as a 'Multi Panel' rather than a basic HMI. The MP 177 features a dedicated SD/Multimedia card slot on the back. By configuring the local retentive storage paths within your WinCC script, the panel will continuously log process values, alarms, and user recipes directly to the storage card even during local network interruptions, preventing any critical industrial data loss.
Recommended Models
6ES5434-4UA11
6ES7288-3AR04-0AA0
6GK1561-4AA02
6ES5441-4UA14
6ES7412-2XG00-0AB0
16267-1/4
6ES5454-4UA13
6DS1916-8RR
6ES7135-0HF01-0XB0
6ES5465-4UA12
6SN1118-0DK23-0AA2
383VA21N1F
6ES5470-4UC12
6GK1901-1BB10-2AE0
39ACM14CAN
6AV6647-0AK11-3AX0
6DD1660-0BJ0
39PSMNAN
6AV6648-0CE11-3AX0
6DD1661-0AE0
39PSR4ANDN 16114-200/01
6DD1681-0CA2
6DD1640-0AD0
39RTMCAN
6DD1601-0AE0
6FC5370-4AM20-0AA0
39VIMCBN
6DD1688-0AD0
6FC5370-8AA20-0AA0
39VIMCCN
Global Business Coverage
North America (USA, Canada)
Europe (Germany, UK, France, Italy, Spain, etc.)
Asia (China, Japan, South Korea, Southeast Asia, India)
Middle East (UAE, Saudi Arabia, etc.)
South America & others (Brazil, Mexico, Australia)
The Amikon Benefit: 100% Original | Factory Sealed | Lowest Lead Times
Get a Quote Now